SV5150
Vortex flow meter. SVM34XXXD0KG/US-100
Reliable detection of flow and medium temperature. Precise linearized analogue output. Suitable for water and water-based media. For installation in pipes. High precision of flow and temperature monitoring
| Number of inputs and outputs: | Number of analogue outputs: 1 |
| Process connection: | threaded connection G 3/4 DN10 |
| Measuring range [°C]: | -40...100 |
| Special feature: | Gold-plated contacts |
| Measuring element: | 1 x Pt 1000; (to DIN EN 60751, class B) |
| Application: | for industrial applications |
| Installation: | connection to pipe by means of an adapter |
| Media: | water; glycol solutions; coolants |
| Medium temperature [°C]: | -40...100 |
| Min. bursting pressure [bar]: | 25 |
| Min. bursting pressure [MPa]: | 2.5 |
| Pressure rating [bar]: | 12 |
| Pressure rating [Mpa]: | 1.2 |
| Note on pressure rating: | up to 40 °C |
| Operating voltage [V]: | 8...33 DC |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Power-on delay time [s]: | < 2 |
| Number of inputs and outputs: | Number of analogue outputs: 1 |
| Total number of outputs: | 1 |
| Output signal: | analogue signal |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20; (water: Q [l/min] = 2,0 x (I - 4 mA); water-glycol: Q [l/min] = 2,0 x (I - 4 mA) - Qo see Figure 2) |
| Max. load [Ω]: | < (Ub - 8 V) / 20 mA; Ub = 24 V: 800 |
| Measuring range: | 1.8...32 l/min 0.265...4.716 m/s |
| 1.8...32 l/min: | 0.265...4.716 m/s |
| Internal heating temperature probe: | 1 K/mW |
| Measuring range [°C]: | -40...100 |
| Accuracy (in the measuring range): | Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water) |
| Repeatability: | 0,2; (% of the final value) |
| Accuracy [K]: | ± 0,3 ± 0,005 x T |
| Response time [s]: | 0.5 |
| Ambient temperature [°C]: | -15...85 |
| Note on ambient temperature: | medium temperature > 0 °C: -30...85 |
| Storage temperature [°C]: | -30...85 |
| Protection: | IP 65 |
| Cavitation: | P(absolute) discharge / P(difference) > 5.5 to avoid cavitation |
| EMC: | EN 61326-2-3 |
| Shock resistance: | DIN EN 60068-2-27 30 g (11 ms) |
| DIN EN 60068-2-27: | 30 g (11 ms) |
| Vibration resistance: | DIN EN 60068-2-6 with water / 10...61 Hz 1 mm with water / 61...2000 Hz 2 g |
| DIN EN 60068-2-6: | with water / 10...61 Hz 1 mm |
| MTTF [years]: | 380 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 79 |
| Materials: | PA 6T |
| Materials (wetted parts): | ETFE; PA 6T; EPDM |
| Tightening torque [Nm]: | 12 |
| Process connection: | threaded connection G 3/4 DN10 |
| Remarks: | MW = measured value MEW = Final value of the measuring range |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Kraj pochodzenia: | CH |
| EAN: | |
| Waga: | 0,08 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |