SV4204
Vortex flow meter with display. SVR12XXX50KG/US-100
Reliable detection of flow and medium temperature. Precise linearized analogue output. Display can be rotated for optimum alignment. Clearly readable colour display with red/green colour change. Suitable for water, deionised water and cooling water
Number of inputs and outputs: | Number of analogue outputs: 2 |
Process connection: | threaded connection G 1/2 DN8 |
Measuring range [°C]: | -10...90 |
Special feature: | Gold-plated contacts |
Application: | for industrial applications |
Media: | water |
Medium temperature [°C]: | -10...90 |
Pressure rating [bar]: | 12 |
Pressure rating [Mpa]: | 1.2 |
Note on pressure rating: | up to 40 °C |
MAWP (for applications according to CRN) [bar]: | 3.9 |
Operating voltage [V]: | 18...30 DC |
Current consumption [mA]: | < 30 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | < 3 |
Number of inputs and outputs: | Number of analogue outputs: 2 |
Total number of outputs: | 2 |
Output signal: | analogue signal |
Number of analogue outputs: | 2 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 500 |
Short-circuit protection: | yes |
Overload protection: | yes |
Measuring range: | 1...20 l/min 0.06...1.2 m³/h |
1...20 l/min: | 0.06...1.2 m³/h |
Display range: | 0...24 l/min 0...1.44 m³/h |
0...24 l/min: | 0...1.44 m³/h |
Resolution: | 0.1 l/min 0.005 m³/h |
0.1 l/min: | 0.005 m³/h |
Analogue start point ASP: | 0...16 l/min 0...0.96 m³/h |
0...16 l/min: | 0...0.96 m³/h |
Analogue end point AEP: | 4...20 l/min 0.24...1.2 m³/h |
4...20 l/min: | 0.24...1.2 m³/h |
In steps of: | 0.1 l/min 0.005 m³/h |
0.1 l/min: | 0.005 m³/h |
Measuring dynamics: | 1:20 |
Measuring range [°C]: | -10...90 |
Display range [°C]: | -30...110 |
Resolution [°C]: | 0.5 |
Analogue start point [°C]: | -10...70 |
Analogue end point [°C]: | 10...90 |
In steps of [°C]: | 0.5 |
Accuracy (in the measuring range): | ± 2 % MEW |
Repeatability: | ± 0,5 % MEW |
Accuracy [K]: | ± 1 |
Response time [s]: | 1; (dAP = 0) |
Damping for the switching output dAP [s]: | 0...5 |
Dynamic response T05 / T09 [s]: | T09 = 6 |
Parameter setting options: | Damping for the analogue output dAA; Display unit |
Ambient temperature [°C]: | 0...60 |
Note on ambient temperature: | medium temperature < 80 °C medium temperature < 90 °C: 0...50 °C |
Storage temperature [°C]: | -20...80 |
Protection: | IP 65; IP 67 |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Shock resistance: | DIN EN 60068-2-27 5 g (11 ms) |
DIN EN 60068-2-27: | 5 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 with water / 10...50 Hz 1 mm with water / 50...2000 Hz 2 g |
DIN EN 60068-2-6: | with water / 10...50 Hz 1 mm |
MTTF [years]: | 342 |
UL approval: | UL Approval no. I002 |
UL Approval no.: | I002 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 439.5 |
Materials: | stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U |
Materials (wetted parts): | stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM |
Tightening torque [Nm]: | 30 |
Process connection: | threaded connection G 1/2 DN8 |
Remarks: | MW = measured value MEW = Final value of the measuring range |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Kraj pochodzenia: | US |
EAN: | |
Waga: | 0,44 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |