SU9004
Ultrasonic flow meter. SUR54HGB50KG/W/US-100-IPF
Reliable detection of flow and medium temperature. Suitable for water, oils and glycol solutions. For installation in pipes. With two scalable analogue outputs. Clearly visible 4-digit LED display
| Number of inputs and outputs: | Number of analogue outputs: 2 |
| Process connection: | threaded connection G 1 1/4 flat seal |
| Measuring range [°C]: | -10...80 |
| Special feature: | Gold-plated contacts |
| Application: | for industrial applications |
| Installation: | connection to pipe by means of an adapter |
| Media: | water; glycol solutions; coolants; oil |
| Note on media: | low-viscosity oils with viscosity: 7...40 mm²/s (40 °C) high-viscosity oils with viscosity: 30...68 mm²/s (40 °C) |
| Medium temperature [°C]: | -10...80 |
| Pressure rating [bar]: | 16 |
| Pressure rating [Mpa]: | 1.6 |
| Operating voltage [V]: | 19...30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA]: | 100 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 10 |
| Number of inputs and outputs: | Number of analogue outputs: 2 |
| Total number of outputs: | 2 |
| Output signal: | analogue signal |
| Number of analogue outputs: | 2 |
| Analogue current output [mA]: | 4...20; (scalable) |
| Max. load [Ω]: | 500 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | 0...200 l/min 0...52.84 gpm |
| 0...200 l/min: | 0...52.84 gpm |
| Display range: | 0...240 l/min 0...63.42 gpm |
| 0...240 l/min: | 0...63.42 gpm |
| Resolution: | 0.1 l/min 0.02 gpm |
| 0.1 l/min: | 0.02 gpm |
| Analogue start point ASP: | 0...160 l/min 0...42.28 gpm |
| 0...160 l/min: | 0...42.28 gpm |
| Analogue end point AEP: | 40...200 l/min 10.28...52.84 gpm |
| 40...200 l/min: | 10.28...52.84 gpm |
| Max. flow rate [l/min]: | 220 |
| In steps of: | 0.1 l/min 0.02 gpm |
| 0.1 l/min: | 0.02 gpm |
| Measuring range [°C]: | -10...80 |
| Resolution [°C]: | 0.2 |
| Analogue start point [°C]: | -10...62 |
| Analogue end point [°C]: | 8...80 |
| In steps of [°C]: | 0.2 |
| Accuracy (in the measuring range): | < ± (3 % MW + 0,2 % MEW) / < ± (8 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) |
| Repeatability: | 1 l/min; 60 l/h; 0,05 gpm; 3 gph |
| Accuracy [K]: | ± 3 (Q > 20 l/min) |
| Response time [s]: | 0.25; (dAP = 0) |
| Damping for the switching output dAP [s]: | 0...1 |
| Dynamic response T05 / T09 [s]: | T09 = 30 (Q > 20 l/min); (water) |
| Ambient temperature [°C]: | -10...60 |
| Storage temperature [°C]: | -25...80 |
| Protection: | IP 67 |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-5 Surge: | 0,5 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| Shock resistance: | DIN IEC 68-2-27 20 g (11 ms) |
| DIN IEC 68-2-27: | 20 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6 5 g (10...2000 Hz) |
| DIN IEC 68-2-6: | 5 g (10...2000 Hz) |
| MTTF [years]: | 203 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 1883 |
| Materials: | housing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA |
| Materials (wetted parts): | stainless steel (1.4404 / 316L); FKM; PPS; Centellen 200 |
| Process connection: | threaded connection G 1 1/4 flat seal |
| Display: | Display unit 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F) measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
| Display unit: | 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F) |
| measured values: | alphanumeric display, 4-digit |
| programming: | alphanumeric display, 4-digit |
| Display unit: | l/min; m³/h; gpm; gph; °C; °F |
| Accessories (supplied): | sealings: 2, Centellen |
| Accessories (optional): | adapter for pipe: 1 x R 1, stainless steel, E40205 adapter for pipe: 1 x 1" NPT, stainless steel, E40206 |
| Remarks: | sealing: only with supplied Centellen seals MW = measured value MEW = Final value of the measuring range |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |
| ECCN: | |
| Kraj pochodzenia: | US |
| EAN: | |
| Waga: | 1,88 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |