SU8000
Ultrasonic flow meter. SUR11HGBFRKG/W/US-100-IPF
Precise measurement of flow, consumption and medium temperature. Suitable for water, oils and glycol solutions. For installation in pipes. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection: | threaded connection G 1 flat seal |
Measuring range [°C]: | -10...80 |
Special feature: | Gold-plated contacts |
Application: | totaliser function; for industrial applications |
Installation: | connection to pipe by means of an adapter |
Media: | water; glycol solutions; coolants; oil |
Note on media: | low-viscosity oils with viscosity: 7...40 mm²/s (40 °C) high-viscosity oils with viscosity: 30...68 mm²/s (40 °C) |
Medium temperature [°C]: | -10...80 |
Pressure rating [bar]: | 16 |
Pressure rating [Mpa]: | 1.6 |
Operating voltage [V]: | 19...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | 100 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 10 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs: | counter reset |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; pulse signal; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250; (per output) |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable) |
Max. load [Ω]: | 500 |
Analogue voltage output [V]: | 0...10; (scalable) |
Min. load resistance [Ω]: | 2000 |
Pulse output: | flow rate meter |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 0...100 l/min 0...6 m³/h |
0...100 l/min: | 0...6 m³/h |
Display range: | 0...120 l/min 0...7.2 m³/h |
0...120 l/min: | 0...7.2 m³/h |
Resolution: | 0.1 l/min 0.005 m³/h |
0.1 l/min: | 0.005 m³/h |
Set point SP: | 0.2...100 l/min 0.01...6 m³/h |
0.2...100 l/min: | 0.01...6 m³/h |
Reset point rP: | 0...99.8 l/min 0...5.99 m³/h |
0...99.8 l/min: | 0...5.99 m³/h |
Analogue start point ASP: | 0...80 l/min 0...4.8 m³/h |
0...80 l/min: | 0...4.8 m³/h |
Analogue end point AEP: | 20...100 l/min 1.2...6 m³/h |
20...100 l/min: | 1.2...6 m³/h |
Max. flow rate: | 110 l/min 6.6 m³/h |
110 l/min: | 6.6 m³/h |
In steps of: | 0.1 l/min 0.005 m³/h |
0.1 l/min: | 0.005 m³/h |
Pulse value: | 0.1 l...1 000 000 m³ |
Pulse length [s]: | 0,025...2 |
Measuring range [°C]: | -10...80 |
Resolution [°C]: | 0.2 |
Set point SP [°C]: | -9.8...80 |
Reset point rP [°C]: | -10...79.8 |
Analogue start point [°C]: | -10...62 |
Analogue end point [°C]: | 8...80 |
In steps of [°C]: | 0.2 |
Accuracy (in the measuring range): | < ± (3 % MW + 0,2 % MEW) / < ± (5 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) |
Repeatability: | 0,2 l/min; 12 l/h; 0,012 m³ /h |
Accuracy [K]: | ± 3 (Q > 1 l/min) |
Response time [s]: | 0.25; (dAP = 0) |
Delay time programmable dS, dr [s]: | 0...50 |
Damping for the switching output dAP [s]: | 0...1 |
Dynamic response T05 / T09 [s]: | T09 = 70 (Q > 5 l/min); (water) |
Parameter setting options: | Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
Ambient temperature [°C]: | -10...60 |
Storage temperature [°C]: | -25...80 |
Protection: | IP 67 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 0,5 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 20 g (11 ms) |
DIN IEC 68-2-27: | 20 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 5 g (10...2000 Hz) |
DIN IEC 68-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 185 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 1711 |
Materials: | housing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA |
Materials (wetted parts): | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
Process connection: | threaded connection G 1 flat seal |
Display: | Display unit 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
Display unit: | 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) |
switching status: | 2 x LED, yellow |
measured values: | alphanumeric display, 4-digit |
programming: | alphanumeric display, 4-digit |
Accessories (supplied): | sealings: 2, Centellen |
Accessories (optional): | adapter for pipe: 1 x R 1/2, stainless steel, E40179 adapter for pipe: 1 x R 3/4, stainless steel, E40180 adapter for pipe: 1 x R 1/2, brass, E40152 adapter for pipe: 1 x R 3/4, brass, E40153 |
Remarks: | MW = measured value MEW = Final value of the measuring range sealing: only with supplied Centellen seals |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |
ECCN: | |
Kraj pochodzenia: | US |
EAN: | |
Waga: | 1,71 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |