SU7001
Ultrasonic flow meter. SUR34HGBFRKG/W/US-100-IPF
Precise measurement of flow, consumption and medium temperature. Suitable for water, oils and glycol solutions. For installation in pipes. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection: | threaded connection G 3/4 flat seal |
Measuring range [°F]: | 14...176 |
Special feature: | Gold-plated contacts |
Application: | totaliser function; for industrial applications |
Installation: | connection to pipe by means of an adapter |
Media: | water; glycol solutions; coolants; oil |
Note on media: | low-viscosity oils with viscosity: 7...40 mm²/s (40 °C) high-viscosity oils with viscosity: 30...68 mm²/s (40 °C) |
Medium temperature [°F]: | 14...176 |
Pressure rating [bar]: | 16 |
Pressure rating [psi]: | 232 |
Operating voltage [V]: | 19...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | 100 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 10 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs: | counter reset |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; pulse signal; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250; (per output) |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable) |
Max. load [Ω]: | 500 |
Analogue voltage output [V]: | 0...10; (scalable) |
Min. load resistance [Ω]: | 2000 |
Pulse output: | flow rate meter |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 0...793 gph 0...13.22 gpm |
0...793 gph: | 0...13.22 gpm |
Display range: | 0...951 gph 0...15.86 gpm |
0...951 gph: | 0...15.86 gpm |
Resolution: | 1 gph 0.02 gpm |
1 gph: | 0.02 gpm |
Set point SP: | 1...793 gph 0.02...13.22 gpm |
1...793 gph: | 0.02...13.22 gpm |
Reset point rP: | 0...791 gph 0...13.2 gpm |
0...791 gph: | 0...13.2 gpm |
Analogue start point ASP: | 0...637 gph 0...10.62 gpm |
0...637 gph: | 0...10.62 gpm |
Analogue end point AEP: | 156...793 gph 2.6...13.22 gpm |
156...793 gph: | 2.6...13.22 gpm |
Max. flow rate: | 951 gph 15.86 gpm |
951 gph: | 15.86 gpm |
In steps of: | 1 gph 0.02 gpm |
1 gph: | 0.02 gpm |
Pulse value: | 0.02...9000 * 10³ gal |
In steps of: | 0.02 gal |
Pulse length [s]: | 0,6...2 |
Measuring range [°F]: | 14...176 |
Resolution [°F]: | 0.5 |
Set point SP [°F]: | 14...176 |
Reset point rP [°F]: | 14...176 |
Analogue start point [°F]: | 14...144 |
Analogue end point [°F]: | 46...176 |
In steps of [°F]: | 0.5 |
Accuracy (in the measuring range): | < ± (3 % MW + 0,2 % MEW) / < ± (5 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) |
Repeatability: | 0,025 gpm; 1,5 gph |
Accuracy [K]: | ± 5,4 (Q > 0,26 gpm) |
Response time [s]: | 0.25; (dAP = 0) |
Delay time programmable dS, dr [s]: | 0...50 |
Damping for the switching output dAP [s]: | 0...1 |
Dynamic response T05 / T09 [s]: | T09 = 70 (Q > 1 gpm); (water) |
Parameter setting options: | Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
Ambient temperature [°F]: | 14...140 |
Storage temperature [°F]: | -13...176 |
Protection: | IP 67 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-5 Surge: | 0,5 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 20 g (11 ms) |
DIN IEC 68-2-27: | 20 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 5 g (10...2000 Hz) |
DIN IEC 68-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 185 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 1505.5 |
Materials: | housing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA |
Materials (wetted parts): | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
Process connection: | threaded connection G 3/4 flat seal |
Display: | Display unit 5 x LED, green (gpm, gph, gal, °F, 10³) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
Display unit: | 5 x LED, green (gpm, gph, gal, °F, 10³) |
switching status: | 2 x LED, yellow |
measured values: | alphanumeric display, 4-digit |
programming: | alphanumeric display, 4-digit |
Accessories (supplied): | sealings: 2, Centellen |
Accessories (optional): | adapter for pipe: 1 x 1/2" NPT, stainless steel, E40191 adapter for pipe: 1 x 1/2" NPT, brass, E40154 |
Remarks: | MW = measured value MEW = Final value of the measuring range sealing: only with supplied Centellen seals |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |
ECCN: | |
Kraj pochodzenia: | US |
EAN: | |
Waga: | 1,51 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |