Ifm SR5906

Control monitor for flow sensors. SRM12XXAKOW/LS-100-IRF

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Reliable monitoring of liquids and gases in pipes. For the connection of flow sensors with large immersion depths. For sensors made of ceramics, high-grade stainless steel and titanium. Easy setting of the switch points for quick set-up. LED bar graph for indication of switch point and flow

Parametry techniczne

Application: Flow monitoring; Wire monitoring
Frequency AC [Hz]: 47...63
Operating voltage tolerance [%]: -15...10
Operating voltage [V]: 90...240 AC
Max. power consumption [VA]: 3.5
Protection class: II
Reverse polarity protection: no
Power-on delay time [s]: 10
Number of channels: 1
Electrical design: relay
Contact rating: 3 A (250 V AC / 30 V DC); (switching cycles at 3 A load: 100.000; type of switch-off: normally open)
Switching cycles (mechanical): 20_Millionen
Switching function flow monitoring: output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed
Short-circuit protection: no
Overload protection: no
Adjustment of the switch point: pushbutton
Ambient temperature [°C]: -20...60
Protection: IP 67; (with sensor attached)
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 30 g (6 ms)
DIN IEC 68-2-27: 30 g (6 ms)
Vibration resistance: DIN IEC 68-2-6 5 g (55...2000 Hz)
DIN IEC 68-2-6: 5 g (55...2000 Hz)
MTTF [years]: 209
Weight [g]: 244.5
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass
Display: function LED, bar graph switching status LED, orange flash in case of wire break
function: LED, bar graph
switching status: LED, orange flash in case of wire break
Required protection: miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting
Remarks: Connection for flow sensor without short-circuit protection / reverse polarity protection. The flow sensor must be directly connected to the control monitor. A connection by means of extension cables is not allowed. Recommendation Check the safe functioning of the unit after a short circuit.
Pack quantity: 1 pcs.
Connection: Connector: 1 x 1/2"

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,24 kg
Długość: 0,00 m
Szerokość: 0,00 m