SR5906
Control monitor for flow sensors. SRM12XXAKOW/LS-100-IRF
Reliable monitoring of liquids and gases in pipes. For the connection of flow sensors with large immersion depths. For sensors made of ceramics, high-grade stainless steel and titanium. Easy setting of the switch points for quick set-up. LED bar graph for indication of switch point and flow
Application: | Flow monitoring; Wire monitoring |
Frequency AC [Hz]: | 47...63 |
Operating voltage tolerance [%]: | -15...10 |
Operating voltage [V]: | 90...240 AC |
Max. power consumption [VA]: | 3.5 |
Protection class: | II |
Reverse polarity protection: | no |
Power-on delay time [s]: | 10 |
Number of channels: | 1 |
Electrical design: | relay |
Contact rating: | 3 A (250 V AC / 30 V DC); (switching cycles at 3 A load: 100.000; type of switch-off: normally open) |
Switching cycles (mechanical): | 20_Millionen |
Switching function flow monitoring: | output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed |
Short-circuit protection: | no |
Overload protection: | no |
Adjustment of the switch point: | pushbutton |
Ambient temperature [°C]: | -20...60 |
Protection: | IP 67; (with sensor attached) |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 30 g (6 ms) |
DIN IEC 68-2-27: | 30 g (6 ms) |
Vibration resistance: | DIN IEC 68-2-6 5 g (55...2000 Hz) |
DIN IEC 68-2-6: | 5 g (55...2000 Hz) |
MTTF [years]: | 209 |
Weight [g]: | 244.5 |
Materials: | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass |
Display: | function LED, bar graph switching status LED, orange flash in case of wire break |
function: | LED, bar graph |
switching status: | LED, orange flash in case of wire break |
Required protection: | miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting |
Remarks: | Connection for flow sensor without short-circuit protection / reverse polarity protection. The flow sensor must be directly connected to the control monitor. A connection by means of extension cables is not allowed. Recommendation Check the safe functioning of the unit after a short circuit. |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x 1/2" |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 0,24 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |