Ifm SQ0500

Flow meter. SQR18DXBFPKG/US-100

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

For low flow rates. Suitable for water and aqueous solutions. Precise measurement of flow, consumption and medium temperature. Fast response time and high response sensitivity. Clearly visible LED display

Parametry techniczne

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection G 1/8
Measuring range [°C]: 0...60
Media: water; hydrous media
Medium temperature [°C]: 0...60
Pressure rating [bar]: 10
Operating voltage [V]: 19...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 110
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 5
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; (configurable)
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Pulse output: consumed quantity meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Short-circuit proof: yes
Overload protection: yes
Measuring range [ml/min]: 1...200
Display range [ml/min]: 0...240
Set point SP [ml/min]: 6...200
Reset point rP [ml/min]: 1...195
Analogue start point ASP [ml/min]: 0...150
Analogue end point AEP [ml/min]: 50...200
In steps of [ml/min]: 1
Measuring dynamics: 1:200
Pulse value: 0.1...2000000000 ml
In steps of: 0.1...1000000 ml
Pulse length [s]: 0,0125...2
Measuring range [°C]: 0...60
Display range [°C]: 0...72
Set point SP [°C]: 1.8...60
Reset point rP [°C]: 0.3...58.5
Analogue start point [°C]: 0...45
Analogue end point [°C]: 15...60
In steps of [°C]: 0.1
Accuracy (in the measuring range): ± (15 % MW + 2 % MEW); (The values apply for the following conditions:; Application: water; Medium temperature: 20 °C; Ambient temperature: 22...28 °C; unit with mounted flow conditioner)
Repeatability: ± 3% MW
Response time [s]: 0.3; (dAP = 0; for rising flow; for falling flow)
Damping for the switching output dAP [s]: 1...5
Damping for the switching output dAP in steps [s]: 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1...5
Parameter setting options: Flow monitoring; quantity meter; Preset counter; Temperature monitoring
Ambient temperature [°C]: 0...60
Storage temperature [°C]: -25...85
Protection: IP 65
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 30 g (11 ms)
DIN IEC 68-2-27: 30 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 5 g (55...2000 Hz)
DIN IEC 68-2-6: 5 g (55...2000 Hz)
MTTF [years]: 231
Weight [g]: 453
Materials: stainless steel (1.4404 / 316L); PC; PBT-GF20; POM; NBR
Materials (wetted parts): stainless steel (1.4404 / 316L); FKM
Process connection: threaded connection G 1/8
Display: Display unit 3 x LED, green (ml/min, ml, °C) function 2 x LED, yellow switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 3 x LED, green (ml/min, ml, °C)
function: 2 x LED, yellow
switching status: 2 x LED, yellow
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Remarks: MW = measured value MEW = Final value of the measuring range Pressure drop without flow conditioner: max. 5 mbar. Pressure drop with flow conditioner: max. 23 mbar.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,45 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m