SQ0500
Flow meter. SQR18DXBFPKG/US-100
For low flow rates. Suitable for water and aqueous solutions. Precise measurement of flow, consumption and medium temperature. Fast response time and high response sensitivity. Clearly visible LED display
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection: | threaded connection G 1/8 |
Measuring range [°C]: | 0...60 |
Media: | water; hydrous media |
Medium temperature [°C]: | 0...60 |
Pressure rating [bar]: | 10 |
Operating voltage [V]: | 19...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 110 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 5 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; pulse signal; (configurable) |
Electrical design: | PNP |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250; (per output) |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable) |
Max. load [Ω]: | 500 |
Pulse output: | consumed quantity meter |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Short-circuit proof: | yes |
Overload protection: | yes |
Measuring range [ml/min]: | 1...200 |
Display range [ml/min]: | 0...240 |
Set point SP [ml/min]: | 6...200 |
Reset point rP [ml/min]: | 1...195 |
Analogue start point ASP [ml/min]: | 0...150 |
Analogue end point AEP [ml/min]: | 50...200 |
In steps of [ml/min]: | 1 |
Measuring dynamics: | 1:200 |
Pulse value: | 0.1...2000000000 ml |
In steps of: | 0.1...1000000 ml |
Pulse length [s]: | 0,0125...2 |
Measuring range [°C]: | 0...60 |
Display range [°C]: | 0...72 |
Set point SP [°C]: | 1.8...60 |
Reset point rP [°C]: | 0.3...58.5 |
Analogue start point [°C]: | 0...45 |
Analogue end point [°C]: | 15...60 |
In steps of [°C]: | 0.1 |
Accuracy (in the measuring range): | ± (15 % MW + 2 % MEW); (The values apply for the following conditions:; Application: water; Medium temperature: 20 °C; Ambient temperature: 22...28 °C; unit with mounted flow conditioner) |
Repeatability: | ± 3% MW |
Response time [s]: | 0.3; (dAP = 0; for rising flow; for falling flow) |
Damping for the switching output dAP [s]: | 1...5 |
Damping for the switching output dAP in steps [s]: | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1...5 |
Parameter setting options: | Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
Ambient temperature [°C]: | 0...60 |
Storage temperature [°C]: | -25...85 |
Protection: | IP 65 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 30 g (11 ms) |
DIN IEC 68-2-27: | 30 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 5 g (55...2000 Hz) |
DIN IEC 68-2-6: | 5 g (55...2000 Hz) |
MTTF [years]: | 231 |
Weight [g]: | 453 |
Materials: | stainless steel (1.4404 / 316L); PC; PBT-GF20; POM; NBR |
Materials (wetted parts): | stainless steel (1.4404 / 316L); FKM |
Process connection: | threaded connection G 1/8 |
Display: | Display unit 3 x LED, green (ml/min, ml, °C) function 2 x LED, yellow switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
Display unit: | 3 x LED, green (ml/min, ml, °C) |
function: | 2 x LED, yellow |
switching status: | 2 x LED, yellow |
measured values: | alphanumeric display, 4-digit |
programming: | alphanumeric display, 4-digit |
Remarks: | MW = measured value MEW = Final value of the measuring range Pressure drop without flow conditioner: max. 5 mbar. Pressure drop with flow conditioner: max. 23 mbar. |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 0,45 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |