SM9601
Magnetic-inductive flow meter. SMN32XGXFRKG/US-100
Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. For use in water cooling circuits. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection: | threaded connection 1 1/2" NPT DN40 |
Measuring range [°F]: | -4...176 |
Special feature: | Gold-plated contacts |
Application: | totaliser function; empty pipe detection; for industrial applications |
Media: | conductive liquids; water; hydrous media |
Note on media: | conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C) |
Medium temperature [°F]: | 14...158 |
Pressure rating [bar]: | 16 |
MAWP (for applications according to CRN) [bar]: | 16.5 |
Operating voltage [V]: | 18...32 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 150 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 5 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs: | counter reset |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250; (per output) |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable) |
Max. load [Ω]: | 500 |
Analogue voltage output [V]: | 0...10; (scalable) |
Min. load resistance [Ω]: | 2000 |
Pulse output: | flow rate meter |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Frequency of the output [Hz]: | 0.1...10000 |
Measuring range: | 80...4800 gph 1.3...80 gpm |
80...4800 gph: | 1.3...80 gpm |
Display range: | -5760...5760 gph -96...96 gpm |
-5760...5760 gph: | -96...96 gpm |
Resolution: | 5 gph 0.1 gpm |
5 gph: | 0.1 gpm |
Set point SP: | 105...4800 gph 1.7...80 gpm |
105...4800 gph: | 1.7...80 gpm |
Reset point rP: | 80...4775 gph 1.3...79.6 gpm |
80...4775 gph: | 1.3...79.6 gpm |
Analogue start point ASP: | 0...3840 gph 0...64 gpm |
0...3840 gph: | 0...64 gpm |
Analogue end point AEP: | 960...4800 gph 16...80 gpm |
960...4800 gph: | 16...80 gpm |
Low flow cut-off LFC: | < 240 gph < 4 gpm |
< 240 gph: | < 4 gpm |
In steps of: | 5 gph 0.1 gpm |
5 gph: | 0.1 gpm |
Measuring dynamics: | 1:60 |
Pulse value: | 0.02...80 E06 gal |
In steps of: | 0.02 gal |
Pulse length [s]: | 0,016...2 |
Measuring range [°F]: | -4...176 |
Display range [°F]: | -40...212 |
Resolution [°F]: | 0.5 |
Set point SP [°F]: | -2...176 |
Reset point rP [°F]: | -3...175 |
Analogue start point [°F]: | -4...140 |
Analogue end point [°F]: | 32...176 |
In steps of [°F]: | 0.5 |
Accuracy (in the measuring range): | ± (0,8 % MW + 0,5 % MEW) |
Repeatability: | ± 0,2% MEW |
Temperature drift: | ± 0,0185 °F / K |
Accuracy [K]: | ± 1 (77 °F; Q > 4 gpm) |
Response time [s]: | 0.35; (dAP = 0) |
Delay time programmable dS, dr [s]: | 0...50 |
Damping for the switching output dAP [s]: | 0...5 |
Dynamic response T05 / T09 [s]: | T09 = 3 (Q > 4 gpm) |
Parameter setting options: | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 CDV |
IO-Link device ID: | 392 d / 00 01 88 h |
Profiles: | Smart Sensor: Process Data Variable; Device Identification |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 3 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 5 |
Ambient temperature [°F]: | 14...140 |
Storage temperature [°F]: | -13...176 |
Protection: | IP 65; IP 67 |
EMC: | DIN EN 60947-5-9 |
Shock resistance: | DIN EN 60068-2-27 20 g (11 ms) |
DIN EN 60068-2-27: | 20 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 5 g (10...2000 Hz) |
DIN EN 60068-2-6: | 5 g (10...2000 Hz) |
MTTF [years]: | 78 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 2755.95 |
Materials: | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U |
Materials (wetted parts): | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM |
Process connection: | threaded connection 1 1/2" NPT DN40 |
Display: | Display unit 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
Display unit: | 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) |
switching status: | 2 x LED, yellow |
measured values: | alphanumeric display, 4-digit |
programming: | alphanumeric display, 4-digit |
Accessories (supplied): | Label |
Remarks: | MW = measured value MEW = Final value of the measuring range |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 2,76 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |