Ifm SM2601

Magnetic-inductive flow meter. SMN21XGXFRKG/US-100

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. Precise empty pipe detection. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display

Parametry techniczne

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection 2" NPT DN50
Measuring range [°F]: -4...176
Special feature: Gold-plated contacts
Application: totaliser function; empty pipe detection; for industrial applications
Media: conductive liquids; water; hydrous media
Note on media: conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C)
Medium temperature [°F]: 14...158
Pressure rating [bar]: 16
Pressure rating [psi]: 232
MAWP (for applications according to CRN) [bar]: 16.5
Operating voltage [V]: 18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 150
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 5
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Inputs: counter reset
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Analogue voltage output [V]: 0...10; (scalable)
Min. load resistance [Ω]: 2000
Pulse output: flow rate meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Frequency of the output [Hz]: 0.1...10000
Measuring range: 80...9600 gph 1.3...160 gpm
80...9600 gph: 1.3...160 gpm
Display range: -11520...11520 gph -190...190 gpm
-11520...11520 gph: -190...190 gpm
Resolution: 5 gph 0.1 gpm
5 gph: 0.1 gpm
Set point SP: 130...9600 gph 2.1...160 gpm
130...9600 gph: 2.1...160 gpm
Reset point rP: 80...9550 gph 1.3...159.2 gpm
80...9550 gph: 1.3...159.2 gpm
Analogue start point ASP: 0...7680 gph 0...128 gpm
0...7680 gph: 0...128 gpm
Analogue end point AEP: 1920...9600 gph 32...160 gpm
1920...9600 gph: 32...160 gpm
Low flow cut-off LFC: < 240 gph < 4 gpm
< 240 gph: < 4 gpm
In steps of: 5 gph 0.1 gpm
5 gph: 0.1 gpm
Measuring dynamics: 1:120
Pulse value: 0.02...160 E06 gal
In steps of: 0.02 gal
Pulse length [s]: 0,008...2
Measuring range [°F]: -4...176
Display range [°F]: -40...212
Resolution [°F]: 0.5
Set point SP [°F]: -2...176
Reset point rP [°F]: -3...175
Analogue start point [°F]: -4...140
Analogue end point [°F]: 32...176
In steps of [°F]: 0.5
Accuracy (in the measuring range): ± (0,8 % MW + 0,5 % MEW)
Repeatability: ± 0,2% MEW
Temperature drift: ± 0,0185 °F / K
Accuracy [K]: ± 1 (77 °F; Q > 4 gpm)
Response time [s]: 0.35; (dAP = 0)
Delay time programmable dS, dr [s]: 0...50
Damping for the switching output dAP [s]: 0...5
Dynamic response T05 / T09 [s]: T09 = 3 (Q > 4 gpm)
Parameter setting options: Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 CDV
IO-Link device ID: 390 d / 00 01 86 h
Profiles: Smart Sensor: Process Data Variable; Device Identification
SIO mode: yes
Required master port type: A
Process data analogue: 3
Process data binary: 2
Min. process cycle time [ms]: 5
Ambient temperature [°F]: 14...140
Storage temperature [°F]: -13...176
Protection: IP 65; IP 67
EMC: DIN EN 60947-5-9
Shock resistance: DIN EN 60068-2-27 20 g (11 ms)
DIN EN 60068-2-27: 20 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 5 g (10...2000 Hz)
DIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]: 78
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 2775
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts): stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM
Process connection: threaded connection 2" NPT DN50
Display: Display unit 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status: 2 x LED, yellow
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Accessories (supplied): Label
Remarks: MW = measured value MEW = Final value of the measuring range
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 2,78 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m