SI6000
Flow monitor. SIS30ABBFPKG/US-100-IPF
Hygienic design for the requirements of the food and beverage industry. Suitable for SIP processes up to 140 °C. LED bar graph for indication of switch point and flow. Extensive range of process adapters in the accessories. Wetted parts made of stainless steel
| Number of inputs and outputs: | Number of digital outputs: 1 |
| Process connection: | Aseptoflex |
| Installation length EL [mm]: | 69.5 |
| Special feature: | Gold-plated contacts |
| Application: | hygienic systems |
| Medium temperature [°C]: | -25...95; (for SIP process: ...140 °C) |
| Pressure rating [bar]: | 30 |
| Application: | hygienic systems |
| Medium temperature [°C]: | -25...95; (for SIP process: ...140 °C) |
| Medium temperature [°C]: | -25...95; (for SIP process: ...140 °C) |
| Operating voltage [V]: | 19...36 DC |
| Current consumption [mA]: | < 60 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 10 |
| Number of inputs and outputs: | Number of digital outputs: 1 |
| Total number of outputs: | 1 |
| Output signal: | switching signal |
| Electrical design: | PNP |
| Number of digital outputs: | 1 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2.5 |
| Permanent current rating of switching output DC [mA]: | 250 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Probe length L [mm]: | 55 |
| Setting range [cm/s]: | 3...300 |
| Greatest sensitivity [cm/s]: | 3...100 |
| Setting range [cm/s]: | 200...3000 |
| Greatest sensitivity [cm/s]: | 200...800 |
| Repeatability [cm/s]: | 1...5 |
| Note on repeatability: | for water 5...100 cm/s; 25 °C Factory setting |
| Temperature drift [cm/s x 1/K]: | 0.1; (for water 5...100 cm/s; 10...70 °C) |
| Temperature gradient [K/min]: | 300 |
| Switch point accuracy [cm/s]: | ± 2...± 10; (for water 5...100 cm/s; 25 °C; Factory setting) |
| Hysteresis [cm/s]: | 2...5; (for water 5...100 cm/s; 25 °C; Factory setting) |
| Response time [s]: | 1...10 |
| Response time [s]: | 1...10 |
| Response time [s]: | 1...10 |
| Adjustment of the switch point: | pushbutton |
| Ambient temperature [°C]: | -25...60 |
| Protection: | IP 67; IP 69K |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
| DIN IEC 68-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN EN 60068-2-6 10 g (55...2000 Hz) |
| DIN EN 60068-2-6: | 10 g (55...2000 Hz) |
| MTTF [years]: | 298 |
| Weight [g]: | 406 |
| Materials: | stainless steel (1.4404 / 316L); PC; PBT-GF20; EPDM/X; O-ring: FKM |
| Materials (wetted parts): | stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4 |
| Process connection: | Aseptoflex |
| Installation length EL [mm]: | 69.5 |
| Display: | function 10 x LED, three-colour |
| function: | 10 x LED, three-colour |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,41 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |