SF323A
Flow sensor for connection to an evaluation unit. SFR12XBK/2G /6M
For applications in hazardous areas. Reliable monitoring of aggressive liquids in pipes. For connection to an evaluation unit. Ceramic materials for contact with the medium. Robust design for use in harsh industrial environments
Probe length L [mm]: | 30 |
Process connection: | G 1/2 external thread |
Media: | Liquids; aggressive media |
Medium temperature [°C]: | 5...70 |
Pressure rating [bar]: | 30 |
Medium temperature [°C]: | 5...70 |
Connection to control monitor: | VS2000 Exi (PTB 01 ATEX 2075) |
Probe length L [mm]: | 30 |
Setting range [cm/s]: | 3...60 |
Greatest sensitivity [cm/s]: | 3...40 |
Temperature gradient [K/min]: | 7 |
Response time [s]: | 2...20 |
Response time [s]: | 2...20 |
Ambient temperature [°C]: | -20...70 |
Protection: | IP 67 |
Approval: | DMT 03 ATEX E091; IECEX BVS 06.0007 |
ATEX marking: | II 2G Ex ia IIC T4 Gb |
Shock resistance: | DIN IEC 68-2-27 40 g (11 ms) |
DIN IEC 68-2-27: | 40 g (11 ms) |
Vibration resistance: | DIN IEC 68-2-6 10 g (55...2000 Hz) |
DIN IEC 68-2-6: | 10 g (55...2000 Hz) |
MTTF [years]: | 7927 |
Max. internal capacitance [nF]: | 1.2 |
Max. internal inductance [µH]: | 6 |
Temperature class: | T4 |
Weight [g]: | 357.5 |
Housing: | threaded type |
Materials: | ceramics (99.7 % Al2O3) |
Materials (wetted parts): | ceramics (99.7 % Al2O3) |
Process connection: | G 1/2 external thread |
Installation length EL [mm]: | 45 |
Remarks: | In principle, the type test according to 94/9/EC (ATEX) only takes atmospheric conditions into account (0.8...1.1 bar). For pressures outside this range use must be assessed and approved by the user. Adhere to the operating instructions and the type test certificate. |
Pack quantity: | 1 pcs. |
Connection: | Cable: 6 m, TPE-S; Maximum cable length: 100 m; 5 x 0.34 mm² |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 0,36 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |