SD6101
Flow rate meter for gases. SDN12DGXFPKG/US-100
Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2). With switching output, analogue output and pulse output. Clearly visible 4-digit LED display
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection: | threaded connection 1/2" NPT DN15 |
Measuring range [°F]: | 32...140 |
Application: | for industrial applications |
Media: | Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
Medium temperature [°F]: | 32...140 |
Pressure rating [bar]: | 16 |
Pressure rating [psi]: | 232 |
MAWP (for applications according to CRN) [bar]: | 16 |
Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 100 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 1 |
Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design: | PNP |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 250; (per output) |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20; (scalable) |
Max. load [Ω]: | 500 |
Pulse output: | consumed quantity meter |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Low flow cut-off LFC: | < 46 scfh < 0.76 scfm 1...5.8 sfs |
< 46 scfh: | < 0.76 scfm |
Measuring dynamics: | 1:300 |
Measuring range: | 15...4310 scfh 0.2...71.8 scfm 2...552 sfs |
15...4310 scfh: | 0.2...71.8 scfm |
Display range: | 0...5170 scfh 0...86.2 scfm 0...663 sfs |
0...5170 scfh: | 0...86.2 scfm |
Resolution: | 5 scfh 0.1 scfm 1 sfs |
5 scfh: | 0.1 scfm |
Set point SP: | 40...4310 scfh 0.7...71.8 scfm 5...552 sfs |
40...4310 scfh: | 0.7...71.8 scfm |
Reset point rP: | 20...4290 scfh 0.4...71.5 scfm 3...550 sfs |
20...4290 scfh: | 0.4...71.5 scfm |
Analogue start point ASP: | 0...3445 scfh 0...57.4 scfm 0...442 sfs |
0...3445 scfh: | 0...57.4 scfm |
Analogue end point AEP: | 860...4310 scfh 14.4...71.8 scfm 110...552 sfs |
860...4310 scfh: | 14.4...71.8 scfm |
In steps of: | 5 scfh 0.1 scfm 1 sfs |
5 scfh: | 0.1 scfm |
Measuring range: | 10...2640 scfh 0.15...44 scfm 1...338.5 sfs |
10...2640 scfh: | 0.15...44 scfm |
Display range: | 0...3170 scfh 0...52.8 scfm 0...406 sfs |
0...3170 scfh: | 0...52.8 scfm |
Resolution: | 5 scfh 0.05 scfm 0.5 sfs |
5 scfh: | 0.05 scfm |
Set point SP: | 25...2640 scfh 0.4...44 scfm 3...338.5 sfs |
25...2640 scfh: | 0.4...44 scfm |
Reset point rP: | 15...2630 scfh 0.2...43.8 scfm 1.5...337 sfs |
15...2630 scfh: | 0.2...43.8 scfm |
Analogue start point ASP: | 0...2110 scfh 0...35.2 scfm 0...271 sfs |
0...2110 scfh: | 0...35.2 scfm |
Analogue end point AEP: | 530...2640 scfh 8.8...44 scfm 67.5...338.5 sfs |
530...2640 scfh: | 8.8...44 scfm |
In steps of: | 5 scfh 0.05 scfm 0.5 sfs |
5 scfh: | 0.05 scfm |
Pulse value: | 0.040...4 000 000 scf |
In steps of: | 0.020...1000 scf |
Pulse length [s]: | 0,007...2 |
Measuring range: | 10...2650 scfh 0.15...44.15 scfm 1...339.5 sfs |
10...2650 scfh: | 0.15...44.15 scfm |
Display range: | 0...3175 scfh 0...52.95 scfm 0...407.5 sfs |
0...3175 scfh: | 0...52.95 scfm |
Resolution: | 5 scfh 0.05 scfm 0.5 sfs |
5 scfh: | 0.05 scfm |
Set point SP: | 25...2650 scfh 0.4...44.15 scfm 3...339.5 sfs |
25...2650 scfh: | 0.4...44.15 scfm |
Reset point rP: | 15...2635 scfh 0.2...43.95 scfm 1.5...338 sfs |
15...2635 scfh: | 0.2...43.95 scfm |
Analogue start point ASP: | 0...2120 scfh 0...35.3 scfm 0...271.5 sfs |
0...2120 scfh: | 0...35.3 scfm |
Analogue end point AEP: | 530...2650 scfh 8.85...44.15 scfm 68...339.5 sfs |
530...2650 scfh: | 8.85...44.15 scfm |
In steps of: | 5 scfh 0.05 scfm 0.5 sfs |
5 scfh: | 0.05 scfm |
Measuring range [°F]: | 32...140 |
Display range [°F]: | 10.5...161.5 |
Resolution [°F]: | 0.5 |
Set point SP [°F]: | 32.5...140 |
Reset point rP [°F]: | 32...139.5 |
Analogue start point [°F]: | 32...118.5 |
Analogue end point [°F]: | 53.5...140 |
In steps of [°F]: | 0.5 |
Repeatability [% of the measured value]: | ± 1,5 |
Accuracy (in the measuring range): | ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15) |
Accuracy [K]: | ± 2; (medium flow in the limit area of the flow measurement range) |
Response time [s]: | 0.1; (dAP = 0) |
Damping for the switching output dAP in steps [s]: | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
Parameter setting options: | Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 |
IO-Link device ID: | 266 d / 00 01 0a h |
Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 3 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 4.1 |
Ambient temperature [°F]: | 32...140 |
Storage temperature [°F]: | -4...185 |
Max. relative air humidity [%]: | 90 |
Protection: | IP 65 |
EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
Vibration resistance: | DIN IEC 68-2-6 5 g (55...2000 Hz) |
DIN IEC 68-2-6: | 5 g (55...2000 Hz) |
MTTF [years]: | 227 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 925.5 |
Materials: | PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM |
Materials (wetted parts): | stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised |
Process connection: | threaded connection 1/2" NPT DN15 |
Display: | Display unit 4 x LED, green (scfm, scfh, scf, °F) function display 1 x LED, yellow switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit |
Display unit: | 4 x LED, green (scfm, scfh, scf, °F) |
function display: | 1 x LED, yellow |
switching status: | 2 x LED, yellow |
measured values: | alphanumeric display, 4-digit |
programming: | alphanumeric display, 4-digit |
Display unit: | scfm; scfh; scf; °F |
Remarks: | MW = measured value MEW = Final value of the measuring range Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 0,93 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |