Ifm SD6001

Compressed air meter. SDN12DGXFPKG/US-100

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Precise measurement of flow, consumption and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting compressed air in industrial use. With switching output, analogue output and pulse output. Clearly visible 4-digit LED display

Parametry techniczne

Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Process connection: threaded connection 1/2" NPT DN15
Measuring range [°F]: 32...140
Application: for industrial applications
Media: compressed air
Note on media: air quality ISO 8573-1 class 141 class 344
Medium temperature [°F]: 32...140
Pressure rating [bar]: 16
Pressure rating [psi]: 232
MAWP (for applications according to CRN) [bar]: 16
Operating voltage [V]: 19...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 100
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 1
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; pulse signal; (configurable)
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250; (per output)
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 500
Pulse output: consumed quantity meter
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: 10...2650 scfh 0.2...44.1 scfm
10...2650 scfh: 0.2...44.1 scfm
Display range: 0...3178 scfh 0...53 scfm
0...3178 scfh: 0...53 scfm
Set point SP: 25...2650 scfh 0.4...44.1 scfm
25...2650 scfh: 0.4...44.1 scfm
Reset point rP: 10...2635 scfh 0.2...43.9 scfm
10...2635 scfh: 0.2...43.9 scfm
Analogue start point ASP: 0...1985 scfh 0...33.1 scfm
0...1985 scfh: 0...33.1 scfm
Analogue end point AEP: 660...2650 scfh 11...44.1 scfm
660...2650 scfh: 11...44.1 scfm
In steps of: 5 scfh 0.1 scfm
5 scfh: 0.1 scfm
Pulse value: 0.040...4 000 000 scf
In steps of: 0.020...1000 scf
Pulse length [s]: 0,045...2
Measuring range [°F]: 32...140
Display range [°F]: 32...140
Repeatability [% of the measured value]: ± 1,5
Accuracy (in the measuring range): ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 / ; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN15)
Accuracy [K]: ± 2; (medium flow in the limit area of the flow measurement range)
Response time [s]: 0.1; (dAP = 0)
Damping for the switching output dAP in steps [s]: 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Parameter setting options: Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit
Ambient temperature [°F]: 32...140
Storage temperature [°F]: -4...185
Max. relative air humidity [%]: 90
Protection: IP 65
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3
Vibration resistance: DIN EN 68000-2-6 5 g (55...2000 Hz)
DIN EN 68000-2-6: 5 g (55...2000 Hz)
MTTF [years]: 227
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 925
Materials: PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminium powder-coated
Materials (wetted parts): stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium
Process connection: threaded connection 1/2" NPT DN15
Display: Display unit 4 x LED, green (scfm, scfh, scf, °F) function display 1 x LED, yellow switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit
Display unit: 4 x LED, green (scfm, scfh, scf, °F)
function display: 1 x LED, yellow
switching status: 2 x LED, yellow
measured values: alphanumeric display, 4-digit
programming: alphanumeric display, 4-digit
Remarks: scf = standard cubic feet scfh = standard cubic feet per hour scfm = standard cubic feet per minute MW = measured value MEW = Final value of the measuring range Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. For information about installation and operation please see the operating instructions.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,93 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m