SD5600
Industrial gas counter. SDR14DGXFRKG/US-100
Precise measurement of flow, consumption, pressure and medium temperature. High accuracy, repeatability and measurement dynamics. For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2) and compressed air. Red/green display for clear identification of the acceptable range. Display can be rotated for optimum alignment
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Process connection: | threaded connection G 1/4 DN8 |
| Measuring range: | -10...60 °C 14...140 °F |
| -10...60 °C: | 14...140 °F |
| Application: | for industrial applications |
| Media: | Argon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air |
| Medium temperature [°C]: | -10...60 |
| Min. bursting pressure [bar]: | 64 |
| Min. bursting pressure [MPa]: | 6.4 |
| Pressure rating [bar]: | 16 |
| Pressure rating [Mpa]: | 1.6 |
| Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA]: | < 80 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 1 |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Inputs: | counter reset |
| Output signal: | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2.5 |
| Permanent current rating of switching output DC [mA]: | 150; (per output) |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20; (scalable) |
| Max. load [Ω]: | 500 |
| Pulse output: | consumed quantity meter |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | 0.8...250 l/min 0.3...82.9 m/s 0.05...15 m³/h |
| 0.8...250 l/min: | 0.3...82.9 m/s |
| Display range: | 0...300 l/min 0...99.5 m/s 0...18 m³/h |
| 0...300 l/min: | 0...99.5 m/s |
| Resolution: | 0.2 l/min 0.1 m/s 0.01 m³/h |
| 0.2 l/min: | 0.1 m/s |
| Set point SP: | 2.2...249.9 l/min 0.7...82.9 m/s 0.13...14.99 m³/h |
| 2.2...249.9 l/min: | 0.7...82.9 m/s |
| Reset point rP: | 0.9...248.7 l/min 0.3...82.5 m/s 0.06...14.92 m³/h |
| 0.9...248.7 l/min: | 0.3...82.5 m/s |
| Analogue start point ASP: | 0...200 l/min 0...66.3 m/s 0...12 m³/h |
| 0...200 l/min: | 0...66.3 m/s |
| Analogue end point AEP: | 50...250 l/min 16.6...82.9 m/s 3...15 m³/h |
| 50...250 l/min: | 16.6...82.9 m/s |
| Low flow cut-off LFC: | 0.3...2.7 l/min 0.1...0.9 m/s 0.02...0.16 m³/h |
| 0.3...2.7 l/min: | 0.1...0.9 m/s |
| In steps of: | 0.1 l/min 0.1 m/s 0.01 m³/h |
| 0.1 l/min: | 0.1 m/s |
| Measuring range [bar]: | -1...16 |
| Display range [bar]: | -1...20 |
| Resolution [bar]: | 0.05 |
| Set point SP [bar]: | -0.92...16 |
| Reset point rP [bar]: | -1...15.92 |
| Analogue start point [bar]: | -1...12.8 |
| Analogue end point [bar]: | 2.2...16 |
| In steps of [bar]: | 0.01 |
| Measuring range: | 0...100000000 m³ 0...353146667.2 scf |
| 0...100000000 m³: | 0...353146667.2 scf |
| Display range: | 0...100000000 m³ 0...353146667.2 scf |
| 0...100000000 m³: | 0...353146667.2 scf |
| Set point SP: | 0.001...10000000 m³ 0.05...353146667.2 scf |
| 0.001...10000000 m³: | 0.05...353146667.2 scf |
| Pulse value: | 0.001...10000000 m³ 0.05...353146667.2 scf |
| 0.001...10000000 m³: | 0.05...353146667.2 scf |
| In steps of: | 0.0001 m³ 0.005 scf |
| 0.0001 m³: | 0.005 scf |
| Pulse length [s]: | 0.01...2 |
| Measuring range: | -10...60 °C 14...140 °F |
| -10...60 °C: | 14...140 °F |
| Display range: | -24...74 °C -11.2...165.2 °F |
| -24...74 °C: | -11.2...165.2 °F |
| Resolution: | 0.2 °C 0.5 °F |
| 0.2 °C: | 0.5 °F |
| Set point SP: | -9.7...60 °C 14.6...140 °F |
| -9.7...60 °C: | 14.6...140 °F |
| Reset point rP: | -10...59.7 °C 14...139.4 °F |
| -10...59.7 °C: | 14...139.4 °F |
| Analogue start point: | -10...46 °C 14...114.8 °F |
| -10...46 °C: | 14...114.8 °F |
| Analogue end point: | 4...60 °C 39.2...140 °F |
| 4...60 °C: | 39.2...140 °F |
| In steps of: | 0.1 °C 0.1 °F |
| 0.1 °C: | 0.1 °F |
| Temperature coefficient [1/K]: | ± 0,07 % MW |
| Accuracy (in the measuring range): | ± (6 % MW + 0,6 % MEW); at medium temperature 23 °C |
| Repeatability: | ± (0,4 % MW + 0,1 % MEW) |
| Repeatability [% of the final value]: | ± 0,2 |
| Characteristics deviation [% of the final value]: | < ± 0,5; (BFSL = Best Fit Straight Line) |
| Greatest TEMPCO of the span [% MEW / 10 K]: | ± 0,15 |
| Greatest TEMPCO of the zero point [% MEW / 10 K]: | ± 0,25 |
| Accuracy [K]: | ± 0,5; (medium flow in the limit area of the flow measurement range) |
| Response time [s]: | 0.1; (dAP = 0) |
| Damping for the switching output dAP [s]: | 0...5 |
| Response time [s]: | 0.05 |
| Dynamic response T05 / T09 [s]: | T09 = 0,5 |
| Parameter setting options: | hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 CDV |
| IO-Link device ID: | 861 d / 00 03 5d h |
| Profiles: | Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 8 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 7.2 |
| Ambient temperature [°C]: | 0...60 |
| Storage temperature [°C]: | -20...85 |
| Max. relative air humidity [%]: | 90 |
| Protection: | IP 65; IP 67 |
| EMC: | DIN EN 60947-5-9 |
| Vibration resistance: | DIN EN 68000-2-6 5 g (10...2000 Hz) |
| DIN EN 68000-2-6: | 5 g (10...2000 Hz) |
| MTTF [years]: | 183 |
| UL approval: | UL Approval no. I012 File number UL E174189 |
| UL Approval no.: | I012 |
| File number UL: | E174189 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for stable gases fluid group 2 |
| Weight [K40]: | 558 |
| Materials: | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM |
| Materials (wetted parts): | EN AW-6082 (aluminium); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
| Process connection: | threaded connection G 1/4 DN8 |
| Display: | colour display 1,44", 128 x 128 pixels 2 x LED, yellow |
| Remarks: | MW = measured value MEW = Final value of the measuring range Standard conditions: 1013.25 mbar / 15 °C / 0 % relative humidity For information about installation and operation please see the operating instructions. |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12 |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,56 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |