SB2257
Flow meter with integrated backflow prevention and display. SBG32KM0FRKG
| Process connection: | threaded connection G 1 1/2 internal thread |
| Measuring range: | -10...100 °C 14...212 °F |
| -10...100 °C: | 14...212 °F |
| Special feature: | Gold-plated contacts |
| Media: | Liquids; oil |
| Note on media: | oil with viscosity: 46 mm²/s (40 °C) |
| Medium temperature [°C]: | -10...100 |
| Pressure rating [bar]: | 63 |
| Note on pressure rating: | at medium temperature >70°C: 50 |
| Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA]: | < 50 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | < 3 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; frequency signal; IO-Link |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2 |
| Max. current load per output [mA]: | 150; (200: ...60 °C; Ambient temperature; 250: ...40 °C; Ambient temperature) |
| Analogue current output [mA]: | 4...20 |
| Max. load [Ω]: | 500 |
| Short-circuit protection: | yes |
| Overload protection: | yes |
| Frequency of the output [Hz]: | 0...10000 |
| Measuring range: | 4...200 l/min 0.24...12 m³/h 65...3170 gph 1.1...52.8 gpm |
| 4...200 l/min: | 0.24...12 m³/h |
| Display range: | 0...240 l/min 0...14.4 m³/h 0...3805 gph 0...63.4 gpm |
| 0...240 l/min: | 0...14.4 m³/h |
| Resolution: | 0.1 l/min 0.01 m³/h 1 gph 0.1 gpm |
| 0.1 l/min: | 0.01 m³/h |
| Set point SP: | 1.4...200 l/min 0.08...12 m³/h 20...3170 gph 0.3...52.8 gpm |
| 1.4...200 l/min: | 0.08...12 m³/h |
| Reset point rP: | 0...198.6 l/min 0...11.92 m³/h 0...3150 gph 0...52.5 gpm |
| 0...198.6 l/min: | 0...11.92 m³/h |
| Frequency end point, FEP: | 13.4...200 l/min 0.8...12 m³/h 210...3170 gph 3.5...52.8 gpm |
| 13.4...200 l/min: | 0.8...12 m³/h |
| In steps of: | 0.02 l/min 0.02 m³/h 5 gph 0.1 gpm |
| 0.02 l/min: | 0.02 m³/h |
| Frequency at the end point FRP [Hz]: | 10...10000 |
| In steps of [Hz]: | 10 |
| Measuring dynamics: | 1:50 |
| In steps of: | 10 Hz |
| Measuring range: | -10...100 °C 14...212 °F |
| -10...100 °C: | 14...212 °F |
| Display range: | -32...122 °C -25.6...251.6 °F |
| -32...122 °C: | -25.6...251.6 °F |
| Resolution: | 0.1 °C 0.1 °F |
| 0.1 °C: | 0.1 °F |
| Set point SP: | -9.3...100 °C 15.2...212 °F |
| -9.3...100 °C: | 15.2...212 °F |
| Reset point rP: | -10...99.3 °C 14...210.8 °F |
| -10...99.3 °C: | 14...210.8 °F |
| In steps of: | 0.1 °C 0.2 °F |
| 0.1 °C: | 0.2 °F |
| Frequency start point, FSP: | -10...78 °C 14...172.4 °F |
| -10...78 °C: | 14...172.4 °F |
| Frequency end point, FEP: | 12...100 °C 53.6...212 °F |
| 12...100 °C: | 53.6...212 °F |
| Frequency at the end point FRP [Hz]: | 10...10000 |
| Accuracy (in the measuring range): | ± 5 % MEW; (Q > 1 l/min; 20...70 °C Medium temperature) |
| Repeatability: | ± 1 % MEW |
| Temperature drift: | 0,029 °C / K |
| Accuracy [K]: | 3 K (25°C; Q > 1 l/min) |
| Response time [s]: | 0.01 |
| Damping for the switching output dAP [s]: | 0...5 |
| In steps of [s]: | 0.1 |
| Damping for the analogue output dAA [s]: | 0...5 |
| In steps of [s]: | 0.1 |
| Dynamic response T05 / T09 [s]: | T09 = 120 (Q > 1 l/min) |
| Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour; calibration factor |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 CDV |
| IO-Link device ID: | 1047 d / 0417 h |
| Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 2 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 3.2 |
| Ambient temperature [°C]: | 0...60 |
| Note on ambient temperature: | medium temperature < 80 °C medium temperature < 100 °C: 0...40 °C |
| Storage temperature [°C]: | -15...80 |
| Protection: | IP 65; IP 67 |
| EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
| Shock resistance: | DIN EN 60068-2-27 20 g (11 ms) |
| DIN EN 60068-2-27: | 20 g (11 ms) |
| Vibration resistance: | DIN EN 60068-2-6 5 g (10...2000 Hz) |
| DIN EN 60068-2-6: | 5 g (10...2000 Hz) |
| MTTF [years]: | 145 |
| UL approval: | UL Approval no. I007 |
| UL Approval no.: | I007 |
| Pressure Equipment Directive: | Sound engineering practice |
| Weight [g]: | 2809.5 |
| Materials: | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated |
| Materials (wetted parts): | stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM |
| Process connection: | threaded connection G 1 1/2 internal thread |
| Switching cycles mechanical: | 10 million |
| Display: | Display unit 6 x LED, green switching status 2 x LED, yellow measured values alphanumeric display, red/green alternating indication 4-digit programming alphanumeric display, 4-digit |
| Display unit: | 6 x LED, green |
| switching status: | 2 x LED, yellow |
| measured values: | alphanumeric display, red/green alternating indication 4-digit |
| programming: | alphanumeric display, 4-digit |
| Remarks: | Recommendation: use a 200-micron filter. All data refer to oil with the following nominal viscosity: 46 mm²/s, 40 °C MW = measured value MEW = Final value of the measuring range |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 2,81 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |