Ifm SA5014

Flow sensor. SAD10XDB50KG/US-100

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Measurement of flow and temperature at the same time. Optimised for water, oils and air. Clearly visible 4-digit LED display. With two scalable analogue outputs. The process connection can be rotated for optimum alignment

Parametry techniczne

Number of inputs and outputs: Number of analogue outputs: 2
Process connection: threaded connection M18 x 1,5 internal thread
Special feature: Gold-plated contacts
Media: water; glycol solutions; air; oils
Note on media: low-viscosity oils with viscosity: ≤ 40 mm²/s (104 °F) high-viscosity oils with viscosity: > 40 mm²/s (104 °F)
Medium temperature [°F]: -4...194
Pressure rating [bar]: 100
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 100
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 10
Number of inputs and outputs: Number of analogue outputs: 2
Total number of outputs: 2
Output signal: analogue signal
Number of analogue outputs: 2
Analogue current output [mA]: 4...20; (scalable)
Max. load [Ω]: 350
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Probe length L [mm]: 45
Operating mode: relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended)
Note on factory setting: Operating mode: relative
Resolution [ft/s]: 0.05
Setting range [ft/s]: 0...19.5
Greatest sensitivity [ft/s]: 0.15...9.85
Analogue start point ASP [ft/s]: 0...7.95
Analogue end point AEP [ft/s]: 1.9...9.85
Resolution [ft/s]: 2
Setting range [ft/s]: 0...656
Greatest sensitivity [ft/s]: 6...328
Analogue start point ASP [ft/s]: 0...264
Analogue end point AEP [ft/s]: 64...328
Measuring range [°F]: -4...194
Resolution [°F]: 0.5
Analogue start point [°F]: -4...169
Analogue end point [°F]: 39...212
In steps of [°F]: 0.5
Temperature drift [cm/s x 1/K]: 0,01 fps x 1/K (< 68 °F; > 158 °F)
Temperature gradient [K/min]: 100
Accuracy: ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions :; water: 68...158 °F; inlet length: 5 ft; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)
Repeatability: 0,05 m/s; (water; flow velocity: 0,05...3 m/s)
Temperature drift: ± 0,003 K/°F
Accuracy [K]: ± 0,3 / ± 1; (water; flow velocity: 1...9,85 fps / air; flow velocity: > 32,8 fps)
Response time [s]: 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
Dynamic response T05 / T09 [s]: 1,5 (T09); (water; flow velocity: 0,3...3 m/s)
Parameter setting options: medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour
Ambient temperature [°F]: -40...176
Storage temperature [°F]: -40...212
Protection: IP 65; IP 67
EMC: DIN EN 60947-5-9
Shock resistance: DIN EN 60068-2-27 50 g (11 ms)
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz)
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]: 179
UL approval: UL Approval no. I004 File number UL E174189
UL Approval no.: I004
File number UL: E174189
Weight [g]: 278
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30
Materials (wetted parts): stainless steel (1.4404 / 316L); Gasket: FKM
Process connection: threaded connection M18 x 1,5 internal thread
Display: Display unit 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³) measured values alphanumeric display, red/green 4-digit
Display unit: 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
measured values: alphanumeric display, red/green 4-digit
Remarks: MW = measured value MEW = Final value of the measuring range
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,28 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m