PY7093
Pressure sensor with display. PN-025-RER14-QFRKG/US/ /V
Red/green display for clear identification of the acceptable range. The process connection can be rotated for optimum alignment. With long-term stability thanks to high overload protection. Robust design for use in harsh industrial environments, two switching outputs, one of which can be configured as an IO-Link output
Output signal: | switching signal; IO-Link; (configurable) |
Measuring range: | 0...25 bar 0...363 psi 0...2.5 MPa |
0...25 bar: | 0...363 psi |
Process connection: | threaded connection G 1/4 internal thread |
Special feature: | Gold-plated contacts |
Measuring element: | ceramic-capacitive pressure measuring cell |
Application: | for industrial applications |
Media: | liquids and gases |
Conditionally suitable for: | For gaseous media the application is limited to max. 25 bar. |
Medium temperature [°C]: | -25...80 |
Min. bursting pressure: | 350 bar 5075 psi 35 MPa |
350 bar: | 5075 psi |
Pressure rating: | 150 bar 2175 psi 15 Mpa |
150 bar: | 2175 psi |
Vacuum resistance [mbar]: | -1000 |
Type of pressure: | relative pressure |
Operating voltage [V]: | 18...30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 35 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | < 0.3 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 2 |
Total number of outputs: | 2 |
Output signal: | switching signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2.5 |
Permanent current rating of switching output DC [mA]: | 150; (200 (...60 °C) 250 (...40 °C)) |
Switching frequency DC [Hz]: | < 170 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 0...25 bar 0...363 psi 0...2.5 MPa |
0...25 bar: | 0...363 psi |
Set point SP: | 0.2...25 bar 4...362 psi 0.02...2.5 MPa |
0.2...25 bar: | 4...362 psi |
Reset point rP: | 0.1...24.9 bar 2...360 psi 0.01...2.49 MPa |
0.1...24.9 bar: | 2...360 psi |
In steps of: | 0.1 bar 2 psi 0.01 MPa |
0.1 bar: | 2 psi |
Switch point accuracy [% of the span]: | < ± 0,5 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span]: | < ± 0,25 |
Long-term stability [% of the span]: | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | 0,4; (-25...80 °C) |
Temperature coefficient span [% of the span / 10 K]: | 0,4; (-25...80 °C) |
Response time [ms]: | < 3 |
Delay time programmable dS, dr [s]: | 0...50 |
Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 |
IO-Link device ID: | 402 d / 00 01 92 h |
Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 1 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 2.3 |
Ambient temperature [°C]: | -25...80 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 65; IP 67 |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 254 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 234.5 |
Materials: | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts): | stainless steel (1.4404 / 316L); ceramics; FKM |
Min. pressure cycles: | 100 million |
Tightening torque [Nm]: | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
Process connection: | threaded connection G 1/4 internal thread |
Switching cycles mechanical: | 100 million |
Restrictor element integrated: | no (can be retrofitted) |
Display: | Display unit 3 x LED, green (bar, psi, MPa) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit |
Display unit: | 3 x LED, green (bar, psi, MPa) |
switching status: | 2 x LED, yellow |
measured values: | alphanumeric display, red/green 4-digit |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
Parameter: | Factory setting |
SP1: | 0.04 MPa |
rP1: | 0.03 MPa |
ou1: | Hnc |
SP2: | 0.35 MPa |
rP2: | 0.30 MPa |
ou2: | Hno |
ds1/ds2: | 0 ms |
dr1/dr2: | 0 ms |
coF: | 0 % |
P-n: | pnp |
ECCN: | |