PY2068
Pressure sensor with display. PN-+,2BRBR14-MFRKG/US /V
Two switching outputs, one of them programmable as analogue output. Clearly visible 4-digit LED display. Country-specific pressure units selectable. With long-term stability thanks to high overload protection. Selectable output polarity
| Output signal: | switching signal; analogue signal; (configurable) |
| Measuring range: | -0.25...0.25 bar -250...250 mbar -3.63...3.63 psi -25...25 kPa |
| -0.25...0.25 bar: | -250...250 mbar |
| Process connection: | threaded connection G 1/4 internal thread |
| Special feature: | Gold-plated contacts |
| Media: | liquids and gases |
| Medium temperature [°C]: | -25...80 |
| Min. bursting pressure: | 30000 mbar 435 psi 3000 kPa |
| 30000 mbar: | 435 psi |
| Pressure rating: | 6000 mbar 87 psi 600 kPa |
| 6000 mbar: | 87 psi |
| Type of pressure: | relative pressure |
| Operating voltage [V]: | 18...32 DC |
| Current consumption [mA]: | < 50 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 0.5 |
| Integrated watchdog: | yes |
| Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; (configurable) |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 1 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2 |
| Permanent current rating of switching output DC [mA]: | 250 |
| Switching frequency DC [Hz]: | 6 |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20; (scalable 1:4) |
| Max. load [Ω]: | (Ub - 10 V) / 20 mA |
| Analogue voltage output [V]: | 0...10; (scalable 1:4) |
| Min. load resistance [Ω]: | 2000 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | -0.25...0.25 bar -250...250 mbar -3.63...3.63 psi -25...25 kPa |
| -0.25...0.25 bar: | -250...250 mbar |
| Set point SP: | -248...250 mbar -3.61...3.63 psi -24.8...25 kPa |
| -248...250 mbar: | -3.61...3.63 psi |
| Reset point rP: | -250...248 mbar -3.63...3.6 psi -25...24.8 kPa |
| -250...248 mbar: | -3.63...3.6 psi |
| Analogue start point: | -250...125 mbar -3.63...1.82 psi -25...12.5 kPa |
| -250...125 mbar: | -3.63...1.82 psi |
| Analogue end point: | -125...250 mbar -1.82...3.63 psi -12.5...25 kPa |
| -125...250 mbar: | -1.82...3.63 psi |
| In steps of: | 1 mbar 0.01 psi 0.1 kPa |
| 1 mbar: | 0.01 psi |
| Switch point accuracy [% of the span]: | < ± 0,2; (Turn down 1:1) |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span]: | < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
| Linearity deviation [% of the span]: | < ± 0,1; (Turn down 1:1) |
| Hysteresis deviation [% of the span]: | < ± 0,1; (Turn down 1:1) |
| Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,2; (0...70 °C) |
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...70 °C) |
| Response time [ms]: | < 100 |
| Damping for the switching output dAP [s]: | 0.1...100 |
| Damping for the analogue output dAA [s]: | 0.1...100 |
| Max. response time analogue output [ms]: | 100 |
| Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
| Ambient temperature [°C]: | -25...80 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 65 |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-5 Surge: | 0,5/1 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
| DIN IEC 68-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 181.26 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 287.5 |
| Materials: | stainless steel (1.4301 / 304); PC; PBT; PA; FKM |
| Materials (wetted parts): | stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles: | 100 million |
| Process connection: | threaded connection G 1/4 internal thread |
| Restrictor element integrated: | no (can be retrofitted) |
| Display: | Display unit 4 x LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
| Display unit: | 4 x LED, green |
| switching status: | LED, yellow |
| function display: | alphanumeric display, 4-digit |
| measured values: | alphanumeric display, 4-digit |
| Display unit: | mbar; kPa; psi; % of the span |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,29 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |