Ifm PX9020

Pressure transmitter with ceramic measuring cell. PA-400-SBR14-B-DVG/US/ /V

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Robust design for use in mobile machines. Precise analogue output. With long-term stability thanks to high overload protection. Lifespan of more than 100 million pressure cycles. High shock and vibration resistance

Parametry techniczne

Output signal: analogue signal
Measuring range [bar]: 0...400
Process connection: threaded connection G 1/4 internal thread
Special feature: Gold-plated contacts
Application: for industrial applications
Media: liquids and gases
Conditionally suitable for: For gaseous media the application is limited to max. 25 bar.
Medium temperature [°C]: -25...90; (on request: -40...90 °C)
Min. bursting pressure [bar]: 1000
Pressure rating [bar]: 600
Type of pressure: relative pressure
Operating voltage [V]: 10...30 DC
Current consumption [mA]: < 18
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Number of inputs and outputs: Number of analogue outputs: 1
Total number of outputs: 1
Output signal: analogue signal
Number of analogue outputs: 1
Analogue voltage output [V]: 0.5...4.5
Min. load resistance [Ω]: 2000
Overload protection: yes
Measuring range [bar]: 0...400
Repeatability [% of the span]: < 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Long-term stability [% of the span]: < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K]: 0,4; (0...80 °C)
Temperature coefficient span [% of the span / 10 K]: 0,4; (0...80 °C)
Step response time analogue output [ms]: 3
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 68; IP 69K
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 30 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 30 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [years]: 550
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 221.5
Materials: stainless steel (1.4404 / 316L); FKM; PA; EPDM/X
Materials (wetted parts): stainless steel (1.4305 / 303); ceramics; FKM
Min. pressure cycles: 100 million
Process connection: threaded connection G 1/4 internal thread
Restrictor element integrated: yes
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Parametry logistyczne

ECCN:
Kraj pochodzenia: RO
EAN:
Waga: 0,22 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m