PV7001
Pressure switch with IO-Link. PV-250-SEG14-UFRVG/US/ /
Compact housing for use where space is restricted. Very high overpressure and vacuum resistance. Robust stainless steel housing with high shock and vibration resistance. Lifespan of more than 60 million pressure cycles. Two programmable switching outputs, one of them with IO-Link communication interface
Output signal: | switching signal; IO-Link; (configurable) |
Measuring range: | 0...250 bar 0...3626 psi 0...25 MPa |
0...250 bar: | 0...3626 psi |
Process connection: | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 |
Measuring element: | metallic thin film cell |
Application: | for industrial applications |
Media: | liquids and gases |
Medium temperature [°C]: | -40...90 |
Min. bursting pressure: | 1200 bar 17400 psi 120 MPa |
1200 bar: | 17400 psi |
Pressure rating: | 625 bar 9060 psi 62.5 Mpa |
625 bar: | 9060 psi |
Note on pressure rating: | static |
Vacuum resistance [mbar]: | -1000 |
Type of pressure: | relative pressure |
Operating voltage [V]: | 18...30 DC |
Current consumption [mA]: | < 15 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | < 0.3 |
Number of inputs and outputs: | Number of digital outputs: 2 |
Total number of outputs: | 2 |
Output signal: | switching signal; IO-Link; (configurable) |
Electrical design: | PNP/NPN |
Number of digital outputs: | 2 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 100 |
Switching frequency DC [Hz]: | < 170 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | 0...250 bar 0...3626 psi 0...25 MPa |
0...250 bar: | 0...3626 psi |
Set point SP: | 2.5...250 bar 37...3626 psi 0.25...25 MPa |
2.5...250 bar: | 37...3626 psi |
Reset point rP: | 1.3...248.8 bar 18...3608 psi 0.13...24.88 MPa |
1.3...248.8 bar: | 18...3608 psi |
In steps of: | 0.1 bar 1 psi 0.01 MPa |
0.1 bar: | 1 psi |
Factory setting: | SP1 = 62.5 bar rP1 = 57.5 bar ou1 = Hno; SP2 = 187.5 bar rP2 = 182.5 bar ou2 = Hno; dS1/dS2 = 0 ms dr1/dr2 = 0 ms coF = 0 % P-n = PnP dAP= 60 ms |
SP1 = 62.5 bar: | rP1 = 57.5 bar |
SP2 = 187.5 bar: | rP2 = 182.5 bar |
dS1/dS2 = 0 ms: | dr1/dr2 = 0 ms |
coF = 0 %: | P-n = PnP |
Switch point accuracy [% of the span]: | < ± 0,5 (nach DIN EN 61298-2) |
Repeatability [% of the span]: | < ± 0,05; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,5 (nach DIN EN 61298-2); (incl. drift when overtightened, zero point and span error, non-linearity, hysteresis) |
Linearity deviation [% of the span]: | < ± 0,1 (BFSL) / < ± 0,2 (LS) |
Hysteresis deviation [% of the span]: | < ± 0,2 |
Long-term stability [% of the span]: | < ± 0,1; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
Temperature coefficient span [% of the span / 10 K]: | < 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
Response time [ms]: | < 3 |
Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 |
IO-Link device ID: | 709 d / 00 02 C5 h |
Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 2 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 5 |
Ambient temperature [°C]: | -40...90 |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67; IP 69K |
EMC: | DIN EN 61326-1 |
Shock resistance: | DIN EN 60068-2-27 500 g (1 ms) |
DIN EN 60068-2-27: | 500 g (1 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 667.77 |
UL approval: | UL Approval no. J016 |
UL Approval no.: | J016 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 64 |
Materials: | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI |
Materials (wetted parts): | stainless steel (1.4305 / 303); 1.4542 (17-4 PH / 630) |
Min. pressure cycles: | 60 million; (at 1.2 times nominal pressure) |
Tightening torque [Nm]: | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
Process connection: | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 |
Process connection sealing: | FKM (to DIN 3869) |
Restrictor element integrated: | yes |
Remarks: | BFSL = Best Fit Straight Line LS = limit value setting |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12 |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 0,06 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |