PU1701
Pressure transmitter. PU-360PSEU96-V-DVG/DE
| Output signal: | analogue signal |
| Measuring range [psi]: | 0...3600 |
| Process connection: | threaded connection 9/16" - 18 UNF external thread |
| Application: | for mobile applications |
| Media: | liquids and gases |
| Medium temperature [°C]: | -40...125 |
| Min. bursting pressure [psi]: | 17400 |
| Pressure rating [psi]: | 9000 |
| Note on pressure rating: | static |
| Vacuum resistance [psi]: | -14.5 |
| Type of pressure: | relative pressure |
| Operating voltage [V]: | 8...32 DC |
| Current consumption [mA]: | < 12 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Number of inputs and outputs: | Number of analogue outputs: 1 |
| Total number of outputs: | 1 |
| Output signal: | analogue signal |
| Number of analogue outputs: | 1 |
| Analogue voltage output [V]: | 0.5...4.5 |
| Min. load resistance [Ω]: | 2000 |
| Short-circuit proof: | yes |
| Overload protection: | yes |
| Measuring range [psi]: | 0...3600 |
| Repeatability [% of the span]: | < ± 0,05; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span]: | < ± 0,8; (incl. drift when overtightened, zero point and span error, non-linearity, hysteresis) |
| Linearity deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS) |
| Hysteresis deviation [% of the span]: | < ± 0,2 |
| Long-term stability [% of the span]: | < ± 0,1; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1 (0...80 °C); < ± 0,2 (-40...0 °C / 80...125 °C) |
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,1 (0...80 °C); < ± 0,2 (-40...0 °C / 80...125 °C) |
| Step response time analogue output [ms]: | 2 |
| Ambient temperature [°C]: | -40...100 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 67; IP 69K |
| EMC: | compliant with UN ECE R10, rev. 5 ISO 11452-2 100 V/m DIN EN 61326-1 |
| ISO 11452-2: | 100 V/m |
| Shock resistance: | DIN EN 60068-2-27 500 g (1 ms) |
| DIN EN 60068-2-27: | 500 g (1 ms) |
| Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 658 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 61.5 |
| Materials: | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PPS |
| Materials (wetted parts): | 1.4542 (17-4 PH / 630) |
| Min. pressure cycles: | 60 million; (at 1.2 times nominal pressure) |
| Tightening torque [Nm]: | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
| Process connection: | threaded connection 9/16" - 18 UNF external thread |
| Process connection sealing: | HNBR (to DIN 3869) |
| Restrictor element integrated: | yes |
| Remarks: | BFSL = Best Fit Straight Line LS = limit value setting |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x DEUTSCH connector (DT04-3P); Maximum cable length: 30 m |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,06 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |