PS308A
Hydrostatic submersible pressure transmitter. SUBMERSIBLE 0,25BAR 5M FEP CABLE 1G/1D
For level measurement in hazardous areas. GL approval to environmental category C, F, EMC 1. Longitudinally watertight cable. Robust stainless steel housing with high ingress resistance. High overall accuracy and long-term stability
Output signal: | analogue signal |
Measuring range: | 0...0.25 bar 0...250 mbar 0...3.63 psi 0...25 kPa |
0...0.25 bar: | 0...250 mbar |
Application: | for industrial applications |
Media: | Liquids |
Medium temperature [°C]: | -10...60; (T6: -10...60 °C; T5: -10...80 °C; T4: -10...85 °C; 1 D, 1/2 D, 2 D (750 mW): -10...40 °C; (650 mW): -10...70 °C; (550 mW): -10...85 °C) |
Min. bursting pressure: | 2.4 bar 35 psi 240 kPa |
2.4 bar: | 35 psi |
Pressure rating: | 2 bar 29 psi 200 kPa |
2 bar: | 29 psi |
Type of pressure: | relative pressure |
Switching amplifiers: | connection to intrinsically safe supply isolators (Ex ia) |
Operating voltage [V]: | 10...30 DC |
Protection class: | III |
Reverse polarity protection: | yes |
Number of inputs and outputs: | Number of analogue outputs: 1 |
Total number of outputs: | 1 |
Output signal: | analogue signal |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 700; (Ub = 24 V; (Ub - 10 V) / 20 mA) |
Short-circuit protection: | yes |
Measuring range: | 0...0.25 bar 0...250 mbar 0...3.63 psi 0...25 kPa |
0...0.25 bar: | 0...250 mbar |
Repeatability [% of the span]: | < 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < 0,25 (BFSL) / 0,5; (incl. linearity, zero and span error (limit value setting)) |
Linearity deviation [% of the span]: | < 0,2 (BFSL) |
Long-term stability [% of the span]: | < 0,2; (per year) |
Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,2; (0...50 °C) |
Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...50 °C) |
Ambient temperature [°C]: | -10...60 |
Note on ambient temperature: | T6: -10...60 °C T5: -10...80 °C T4: -10...85 °C 1 D, 1/2 D, 2 D (750 mW): -10...40 °C 1 D, 1/2 D, 2 D (650 mW): -10...70 °C 1 D, 1/2 D, 2 D (550 mW): -10...85 °C |
Storage temperature [°C]: | -10...60 |
Protection: | IP 68 |
Approval: | BVS 10 ATEX E 132 X; IECEx BVS 10.0085 X |
ATEX marking: | I M1 Ex ia I Ma |
MTTF [years]: | 969 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [g]: | 656.5 |
Materials: | stainless steel (1.4571/316Ti ) |
Pack quantity: | 1 pcs. |
Connection: | Cable: 5 m, FEP, Ø 7.5 mm |
ECCN: | |
Kraj pochodzenia: | DE |
EAN: | |
Waga: | 0,66 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |