For level measurement in hazardous areas. GL approval to environmental category C, F, EMC 1. Longitudinally watertight cable. Robust stainless steel housing with high ingress resistance. High overall accuracy and long-term stability

Parametry techniczne

Output signal: analogue signal
Measuring range: 0...0.25 bar 0...250 mbar 0...3.63 psi 0...25 kPa
0...0.25 bar: 0...250 mbar
Application: for industrial applications
Media: Liquids
Medium temperature [°C]: -10...60; (T6: -10...60 °C; T5: -10...80 °C; T4: -10...85 °C; 1 D, 1/2 D, 2 D (750 mW): -10...40 °C; (650 mW): -10...70 °C; (550 mW): -10...85 °C)
Min. bursting pressure: 2.4 bar 35 psi 240 kPa
2.4 bar: 35 psi
Pressure rating: 2 bar 29 psi 200 kPa
2 bar: 29 psi
Type of pressure: relative pressure
Switching amplifiers: connection to intrinsically safe supply isolators (Ex ia)
Operating voltage [V]: 10...30 DC
Protection class: III
Reverse polarity protection: yes
Number of inputs and outputs: Number of analogue outputs: 1
Total number of outputs: 1
Output signal: analogue signal
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: 700; (Ub = 24 V; (Ub - 10 V) / 20 mA)
Short-circuit protection: yes
Measuring range: 0...0.25 bar 0...250 mbar 0...3.63 psi 0...25 kPa
0...0.25 bar: 0...250 mbar
Repeatability [% of the span]: < 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < 0,25 (BFSL) / 0,5; (incl. linearity, zero and span error (limit value setting))
Linearity deviation [% of the span]: < 0,2 (BFSL)
Long-term stability [% of the span]: < 0,2; (per year)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,2; (0...50 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,2; (0...50 °C)
Ambient temperature [°C]: -10...60
Note on ambient temperature: T6: -10...60 °C T5: -10...80 °C T4: -10...85 °C 1 D, 1/2 D, 2 D (750 mW): -10...40 °C 1 D, 1/2 D, 2 D (650 mW): -10...70 °C 1 D, 1/2 D, 2 D (550 mW): -10...85 °C
Storage temperature [°C]: -10...60
Protection: IP 68
Approval: BVS 10 ATEX E 132 X; IECEx BVS 10.0085 X
ATEX marking: I M1 Ex ia I Ma
MTTF [years]: 969
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 656.5
Materials: stainless steel (1.4571/316Ti )
Pack quantity: 1 pcs.
Connection: Cable: 5 m, FEP, Ø 7.5 mm

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,66 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m