PQ7834
Pressure sensor for pneumatics. PQ-010-RHR18-QFPKG/AS/
Reliable monitoring of the system pressure in pneumatics and in compressed air systems. Very high overpressure and vacuum resistance. Clearly visible slanted LED display. Red/green display for clear identification of the acceptable range. Two switching outputs, one of which can be configured as diagnostic output
| Output signal: | switching signal | 
| Measuring range: | -1...10 bar -15...145 psi -30...296 inHg -100...1000 kPa | 
| -1...10 bar: | -15...145 psi | 
| Process connection: | threaded connection G 1/8 internal thread | 
| Special feature: | Gold-plated contacts | 
| Application: | for industrial applications | 
| Media: | compressed air | 
| Conditionally suitable for: | other media on request | 
| Medium temperature [°C]: | 0...60 | 
| Min. bursting pressure: | 30 bar 435 psi 886 inHg 3000 kPa | 
| 30 bar: | 435 psi | 
| Pressure rating: | 20 bar 290 psi 591 inHg 2000 kPa | 
| 20 bar: | 290 psi | 
| Vacuum resistance [mbar]: | -1000 | 
| Type of pressure: | relative pressure; vacuum | 
| Operating voltage [V]: | 18...32 DC; (according to EN 50178 SELV/PELV) | 
| Current consumption [mA]: | < 50 | 
| Min. insulation resistance [MΩ]: | 100; (500 V DC) | 
| Protection class: | III | 
| Reverse polarity protection: | yes | 
| Overvoltage protection: | yes; (< 40 V) | 
| Power-on delay time [s]: | 0.3 | 
| Integrated watchdog: | yes | 
| Number of inputs and outputs: | Number of digital outputs: 2 | 
| Total number of outputs: | 2 | 
| Output signal: | switching signal | 
| Electrical design: | PNP | 
| Number of digital outputs: | 2 | 
| Output function: | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V]: | 2 | 
| Permanent current rating of switching output DC [mA]: | 100 | 
| Switching frequency DC [Hz]: | < 200 | 
| Short-circuit protection: | yes | 
| Type of short-circuit protection: | pulsed | 
| Measuring range: | -1...10 bar -15...145 psi -30...296 inHg -100...1000 kPa | 
| -1...10 bar: | -15...145 psi | 
| Set point SP: | -0.9...10 bar -13...145 psi -26...296 inHg -90...1000 kPa | 
| -0.9...10 bar: | -13...145 psi | 
| Reset point rP: | -0.95...9.95 bar -14...144 psi -28...294 inHg -95...995 kPa | 
| -0.95...9.95 bar: | -14...144 psi | 
| In steps of: | 0.05 bar 1 psi 2 inHg 5 kPa | 
| 0.05 bar: | 1 psi | 
| Switch point accuracy [% of the span]: | < ± 0,5 | 
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) | 
| Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | 
| Hysteresis deviation [% of the span]: | < ± 0,25 | 
| Long-term stability [% of the span]: | < ± 0,05; (per 6 months) | 
| Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (0...60 °C) | 
| Temperature coefficient span [% of the span / 10 K]: | 0,2; (0...60 °C) | 
| Response time [ms]: | < 2.5 | 
| Delay time programmable dS, dr [s]: | 0; 0,002...5 | 
| Parameter setting options: | hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit | 
| Ambient temperature [°C]: | 0...70 | 
| Storage temperature [°C]: | -25...85 | 
| Protection: | IP 65 | 
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V | 
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD | 
| EN 61000-4-3 HF radiated: | 10 V/m | 
| EN 61000-4-4 Burst: | 2 kV | 
| EN 61000-4-5 Surge: | 0,5/1 kV | 
| EN 61000-4-6 HF conducted: | 10 V | 
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) | 
| DIN IEC 68-2-27: | 50 g (11 ms) | 
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) | 
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) | 
| MTTF [years]: | 455 | 
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | 
| Weight [K40]: | 84.5 | 
| Materials: | PBT; FKM; polyester | 
| Materials (wetted parts): | brass; FKM; silicon (coated); PBT | 
| Min. pressure cycles: | 50 million | 
| Process connection: | threaded connection G 1/8 internal thread | 
| Display: | Display unit 4 x LED, green switching status 2 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit | 
| Display unit: | 4 x LED, green | 
| switching status: | 2 x LED, yellow | 
| function display: | alphanumeric display, 4-digit | 
| measured values: | alphanumeric display, 4-digit | 
| Display unit: | bar; kPa; psi; inHg | 
| Accessories (optional): | mounting set for DIN rail: TH 35-7,5 / EN60715, E37340 Thread extension: 1/8", E30075 push-in air fitting for tube: Ø 6 mm, E30076 push-in air fitting for tube: Ø 8 mm, E30077 | 
| Pack quantity: | 1 pcs. | 
| Connection: | Connector: 1 x M8; Contacts: gold-plated | 
| ECCN: | |
| Kraj pochodzenia: | RO | 
| EAN: | |
| Waga: | 0,08 kg | 
| Długość: | 0,00 m | 
| Szerokość: | 0,00 m | 
| Wysokość: | 0,00 m |