Ifm PQ3809

Pressure sensor for pneumatics. PQ-1-1-KHR18-KFPKG/AS/

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Reliable monitoring of the system pressure in pneumatics and in compressed air systems. Very high overpressure and vacuum resistance. Clearly visible slanted LED display. Red/green display for clear identification of the acceptable range. With programmable switching output and analogue output

Parametry techniczne

Output signal: switching signal; analogue signal; IO-Link; (configurable)
Measuring range: -1...1 bar -1000...1000 mbar -14.6...14.6 psi -29.4...29.4 inHg -100...100 kPa
-1...1 bar: -1000...1000 mbar
Process connection: threaded connection G 1/8 internal thread internal thread:M5
Special feature: Gold-plated contacts
Application: for industrial applications
Conditionally suitable for: other media on request
Medium temperature [°C]: 0...60
Min. bursting pressure: 30 bar 435 psi 886 inHg 3000 kPa
30 bar: 435 psi
Note on min. burst pressure: max. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354,4 inHg / 1,2 MPa
Pressure rating: 20 bar 290 psi 591 inHg 2000 kPa
20 bar: 290 psi
Vacuum resistance [mbar]: -1000
Type of pressure: relative pressure; differential pressure; vacuum
Operating voltage [V]: 18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 50
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Overvoltage protection: yes; (< 40 V)
Power-on delay time [s]: 0.5
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link; (configurable)
Electrical design: PNP
Number of digital outputs: 1
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 100
Switching frequency DC [Hz]: < 100
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: 500
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Measuring range: -1...1 bar -1000...1000 mbar -14.6...14.6 psi -29.4...29.4 inHg -100...100 kPa
-1...1 bar: -1000...1000 mbar
Set point SP: -0.98...1 bar -14.2...14.6 psi -28.8...29.4 inHg -98...100 kPa
-0.98...1 bar: -14.2...14.6 psi
Reset point rP: -0.99...0.99 bar -14.4...14.4 psi -29.1...29.1 inHg -99...99 kPa
-0.99...0.99 bar: -14.4...14.4 psi
In steps of: 0.01 bar 0.2 psi 0.3 inHg 1 kPa
0.01 bar: 0.2 psi
Switch point accuracy [% of the span]: < ± 0,5
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]: < ± 0,25
Long-term stability [% of the span]: < ± 0,05; (per 6 months)
Temperature coefficient zero point [% of the span / 10 K]: 0,2; (0...60 °C)
Temperature coefficient span [% of the span / 10 K]: 0,2; (0...60 °C)
Response time [ms]: < 6
Delay time programmable dS, dr [s]: 0; 0,002...5
Step response time analogue output [ms]: 6
Parameter setting options: hysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9 FDIS
IO-Link device ID: 366 d / 00 01 6E h
Profiles: Smart Sensor: Process Data Variable; Device Identification
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: 0...70
Storage temperature [°C]: -25...85
Protection: IP 65
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3
Shock resistance: DIN EN 60068-2-27 50 g (11 ms)
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz)
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]: 437
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [K40]: 86.5
Materials: PBT; FKM; polyester
Materials (wetted parts): brass; FKM; silicon (coated); PBT
Min. pressure cycles: 50 million
Process connection: threaded connection G 1/8 internal thread internal thread:M5
Display: Display unit 4 x LED, green switching status 1 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit
Display unit: 4 x LED, green
switching status: 1 x LED, yellow
function display: alphanumeric display, 4-digit
measured values: alphanumeric display, 4-digit
Display unit: bar; kPa; psi; inHg
Pack quantity: 1 pcs.
Connection: Connector: 1 x M8; Contacts: gold-plated

Parametry logistyczne

ECCN:
Kraj pochodzenia: RO
EAN:
Waga: 0,09 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m