PQ3809
Pressure sensor for pneumatics. PQ-1-1-KHR18-KFPKG/AS/
Reliable monitoring of the system pressure in pneumatics and in compressed air systems. Very high overpressure and vacuum resistance. Clearly visible slanted LED display. Red/green display for clear identification of the acceptable range. With programmable switching output and analogue output
Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
Measuring range: | -1...1 bar -1000...1000 mbar -14.6...14.6 psi -29.4...29.4 inHg -100...100 kPa |
-1...1 bar: | -1000...1000 mbar |
Process connection: | threaded connection G 1/8 internal thread internal thread:M5 |
Special feature: | Gold-plated contacts |
Application: | for industrial applications |
Conditionally suitable for: | other media on request |
Medium temperature [°C]: | 0...60 |
Min. bursting pressure: | 30 bar 435 psi 886 inHg 3000 kPa |
30 bar: | 435 psi |
Note on min. burst pressure: | max. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354,4 inHg / 1,2 MPa |
Pressure rating: | 20 bar 290 psi 591 inHg 2000 kPa |
20 bar: | 290 psi |
Vacuum resistance [mbar]: | -1000 |
Type of pressure: | relative pressure; differential pressure; vacuum |
Operating voltage [V]: | 18...32 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA]: | < 50 |
Min. insulation resistance [MΩ]: | 100; (500 V DC) |
Protection class: | III |
Reverse polarity protection: | yes |
Overvoltage protection: | yes; (< 40 V) |
Power-on delay time [s]: | 0.5 |
Integrated watchdog: | yes |
Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs: | 2 |
Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design: | PNP |
Number of digital outputs: | 1 |
Output function: | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 100 |
Switching frequency DC [Hz]: | < 100 |
Number of analogue outputs: | 1 |
Analogue current output [mA]: | 4...20 |
Max. load [Ω]: | 500 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Measuring range: | -1...1 bar -1000...1000 mbar -14.6...14.6 psi -29.4...29.4 inHg -100...100 kPa |
-1...1 bar: | -1000...1000 mbar |
Set point SP: | -0.98...1 bar -14.2...14.6 psi -28.8...29.4 inHg -98...100 kPa |
-0.98...1 bar: | -14.2...14.6 psi |
Reset point rP: | -0.99...0.99 bar -14.4...14.4 psi -29.1...29.1 inHg -99...99 kPa |
-0.99...0.99 bar: | -14.4...14.4 psi |
In steps of: | 0.01 bar 0.2 psi 0.3 inHg 1 kPa |
0.01 bar: | 0.2 psi |
Switch point accuracy [% of the span]: | < ± 0,5 |
Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Hysteresis deviation [% of the span]: | < ± 0,25 |
Long-term stability [% of the span]: | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (0...60 °C) |
Temperature coefficient span [% of the span / 10 K]: | 0,2; (0...60 °C) |
Response time [ms]: | < 6 |
Delay time programmable dS, dr [s]: | 0; 0,002...5 |
Step response time analogue output [ms]: | 6 |
Parameter setting options: | hysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit |
Communication interface: | IO-Link |
Transmission type: | COM2 (38,4 kBaud) |
IO-Link revision: | 1.1 |
SDCI standard: | IEC 61131-9 FDIS |
IO-Link device ID: | 366 d / 00 01 6E h |
Profiles: | Smart Sensor: Process Data Variable; Device Identification |
SIO mode: | yes |
Required master port type: | A |
Process data analogue: | 1 |
Process data binary: | 2 |
Min. process cycle time [ms]: | 2.3 |
Ambient temperature [°C]: | 0...70 |
Storage temperature [°C]: | -25...85 |
Protection: | IP 65 |
EMC: | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
DIN EN 60068-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 437 |
Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight [K40]: | 86.5 |
Materials: | PBT; FKM; polyester |
Materials (wetted parts): | brass; FKM; silicon (coated); PBT |
Min. pressure cycles: | 50 million |
Process connection: | threaded connection G 1/8 internal thread internal thread:M5 |
Display: | Display unit 4 x LED, green switching status 1 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
Display unit: | 4 x LED, green |
switching status: | 1 x LED, yellow |
function display: | alphanumeric display, 4-digit |
measured values: | alphanumeric display, 4-digit |
Display unit: | bar; kPa; psi; inHg |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M8; Contacts: gold-plated |
ECCN: | |
Kraj pochodzenia: | RO |
EAN: | |
Waga: | 0,09 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |