PP004E
Pressure switch with ceramic measuring cell. PP-010-RBG14-QFPKG/US/ /V
Suited for use in mobile machines. Two switching outputs, one of which can be configured as diagnostic output. High shock and vibration resistance. Excellent EMC resistance. User-friendly communication via IO-Link
| Output signal: | switching signal; IO-Link; (configurable) |
| Measuring range: | -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa |
| -1...10 bar: | -14.5...145 psi |
| Process connection: | threaded connection G 1/4 external thread internal thread:M5 |
| Application: | for mobile applications |
| Media: | liquids and gases |
| Medium temperature [°C]: | -25...90 |
| Min. bursting pressure: | 150 bar 2175 psi 15 MPa |
| 150 bar: | 2175 psi |
| Pressure rating: | 75 bar 1087 psi 7.5 Mpa |
| 75 bar: | 1087 psi |
| Type of pressure: | relative pressure; vacuum |
| Operating voltage [V]: | 9.6...36 DC; (communication mode: 18...32) |
| Current consumption [mA]: | < 45 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 0.3 |
| Number of inputs and outputs: | Number of digital outputs: 2 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; IO-Link; (configurable) |
| Electrical design: | PNP |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2 |
| Permanent current rating of switching output DC [mA]: | 250 |
| Switching frequency DC [Hz]: | 170 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | -1...10 bar -14.5...145 psi -100...1000 kPa -0.1...1 MPa |
| -1...10 bar: | -14.5...145 psi |
| Set point SP: | -0.9...10 bar -13...145 psi -0.09...1 MPa |
| -0.9...10 bar: | -13...145 psi |
| Reset point rP: | -0.95...9.95 bar -14...144 psi -0.095...0.995 MPa |
| -0.95...9.95 bar: | -14...144 psi |
| In steps of: | 0.05 bar 1 psi 0.005 MPa |
| 0.05 bar: | 1 psi |
| Factory setting: | SP1 = 2.50 bar rP1 = 2.30 bar SP2 = 7.50 bar rP2 = 7.30 bar OUT1 = Hno OUT2 = Hno |
| Switch point accuracy [% of the span]: | < ± 0,5 |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span]: | < ± 0,1 |
| Long-term stability [% of the span]: | < ± 0,1; (per year) |
| Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (0...80 °C) |
| Temperature coefficient span [% of the span / 10 K]: | 0,2; (0...80 °C) |
| Response time [ms]: | < 3 |
| Damping for the switching output dAP in steps [s]: | 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500 |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.0 |
| IO-Link device ID: | 6 d / 00 00 06 h |
| Profiles: | no profile |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 1 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 2.3 |
| Ambient temperature [°C]: | -25...85 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 68; (7 days / 1 m water depth / 0.1 bar) |
| EMC: | immunity EN 61000-6-2 EN 61000-4-2 ESD 4 kV contact discharge / 15 kV air discharge EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 0,5 kV supply / 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V immunity ECE R 10, Rev. 5 absorber chamber test to ISO 11452-2: 80 V/m EN 50155 Klasse T3, C1, S1 |
| immunity: | EN 61000-6-2 |
| EN 61000-4-2 ESD: | 4 kV contact discharge / 15 kV air discharge |
| EN 61000-4-3 HF radiated: | 20 V/m |
| EN 61000-4-4 Burst: | 4 kV coupling clamp |
| EN 61000-4-5 Surge: | 0,5 kV supply / 1 kV signal for DC units |
| EN 61000-4-6 HF conducted: | 10 V |
| immunity: | ECE R 10, Rev. 5 |
| absorber chamber test to ISO 11452-2:: | 80 V/m |
| EN 50155: | Klasse T3, C1, S1 |
| Shock resistance: | DIN IEC 60068-2-27 / DIN IEC 60068-2-29 1000 g DIN EN 61373 category 3 |
| DIN IEC 60068-2-27 / DIN IEC 60068-2-29: | 1000 g |
| DIN EN 61373: | category 3 |
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) DIN EN 60068-2-64 14 g DIN EN 61373 category 2 |
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
| DIN EN 60068-2-64: | 14 g |
| DIN EN 61373: | category 2 |
| MTTF [years]: | 310 |
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g]: | 224 |
| Materials: | stainless steel (1.4301 / 304); FKM; EPDM/X; PA |
| Materials (wetted parts): | stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles: | 100 million |
| Process connection: | threaded connection G 1/4 external thread internal thread:M5 |
| Restrictor element integrated: | no (can be retrofitted) |
| Display: | operation 2 x LED, green switching status 2 x LED, yellow |
| operation: | 2 x LED, green |
| switching status: | 2 x LED, yellow |
| Teach function: | yes |
| Remarks: | with reference to UL: "limited voltage" with overcurrent protection in accordance with UL508 |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12 |
| ECCN: | |
| Kraj pochodzenia: | RO |
| EAN: | |
| Waga: | 0,22 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |