Pressure switch with ceramic measuring cell. PP-400-SBG14-QFPKG/US/ /V

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Suited for use in mobile machines. Two switching outputs, one of which can be configured as diagnostic output. High shock and vibration resistance. Excellent EMC resistance. User-friendly communication via IO-Link

Parametry techniczne

Output signal: switching signal; IO-Link; (configurable)
Measuring range: 0...400 bar 0...5800 psi 0...40 MPa
0...400 bar: 0...5800 psi
Process connection: threaded connection G 1/4 external thread internal thread:M5
Application: for mobile applications
Media: liquids and gases
Conditionally suitable for: use in gases at pressures > 25 bar only on request
Medium temperature [°C]: -25...90
Min. bursting pressure: 1000 bar 14500 psi 100 MPa
1000 bar: 14500 psi
Pressure rating: 600 bar 8700 psi 60 Mpa
600 bar: 8700 psi
Type of pressure: relative pressure
Operating voltage [V]: 9.6...36 DC; (communication mode: 18...32)
Current consumption [mA]: < 45
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 0.3
Number of inputs and outputs: Number of digital outputs: 2
Total number of outputs: 2
Output signal: switching signal; IO-Link; (configurable)
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Switching frequency DC [Hz]: 170
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: 0...400 bar 0...5800 psi 0...40 MPa
0...400 bar: 0...5800 psi
Set point SP: 4...400 bar 60...5790 psi 0.4...40 MPa
4...400 bar: 60...5790 psi
Reset point rP: 2...398 bar 30...5760 psi 0.2...39.8 MPa
2...398 bar: 30...5760 psi
In steps of: 2 bar 30 psi 0.2 MPa
2 bar: 30 psi
Factory setting: SP1 = 100 bar rP1 = 92 bar SP2 = 300 bar rP2 = 292 bar OUT1 = Hno OUT2 = Hno
Switch point accuracy [% of the span]: < ± 0,5
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]: < ± 0,1
Long-term stability [% of the span]: < ± 0,1; (per year)
Temperature coefficient zero point [% of the span / 10 K]: 0,2; (0...80 °C)
Temperature coefficient span [% of the span / 10 K]: 0,2; (0...80 °C)
Response time [ms]: < 3
Damping for the switching output dAP in steps [s]: 0,003 - 0,006 - 0,010 - 0,017 - 0,060 - 0,125 - 0,250 - 0,500
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.0
IO-Link device ID: 2 d / 00 00 02 h
Profiles: no profile
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -25...85
Storage temperature [°C]: -40...100
Protection: IP 68; (7 days / 1 m water depth / 0.1 bar)
EMC: immunity EN 61000-6-2 EN 61000-4-2 ESD 4 kV contact discharge / 15 kV air discharge EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 4 kV coupling clamp EN 61000-4-5 Surge 0,5 kV supply / 1 kV signal for DC units EN 61000-4-6 HF conducted 10 V immunity ECE R 10, Rev. 5 absorber chamber test to ISO 11452-2: 80 V/m EN 50155 Klasse T3, C1, S1
immunity: EN 61000-6-2
EN 61000-4-2 ESD: 4 kV contact discharge / 15 kV air discharge
EN 61000-4-3 HF radiated: 20 V/m
EN 61000-4-4 Burst: 4 kV coupling clamp
EN 61000-4-5 Surge: 0,5 kV supply / 1 kV signal for DC units
EN 61000-4-6 HF conducted: 10 V
immunity: ECE R 10, Rev. 5
absorber chamber test to ISO 11452-2:: 80 V/m
EN 50155: Klasse T3, C1, S1
Shock resistance: DIN IEC 60068-2-27 / DIN IEC 60068-2-29 1000 g DIN EN 61373 category 3
DIN IEC 60068-2-27 / DIN IEC 60068-2-29: 1000 g
DIN EN 61373: category 3
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz) DIN EN 60068-2-64 14 g DIN EN 61373 category 2
DIN IEC 68-2-6: 20 g (10...2000 Hz)
DIN EN 60068-2-64: 14 g
DIN EN 61373: category 2
MTTF [years]: 310
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 218.5
Materials: stainless steel (1.4301 / 304); FKM; EPDM/X; PA
Materials (wetted parts): stainless steel (1.4305 / 303); ceramics; FKM
Min. pressure cycles: 100 million
Process connection: threaded connection G 1/4 external thread internal thread:M5
Restrictor element integrated: yes
Display: operation 2 x LED, green switching status 2 x LED, yellow
operation: 2 x LED, green
switching status: 2 x LED, yellow
Teach function: yes
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,22 kg
Długość: 0,00 m
Szerokość: 0,00 m