Ifm PN2028

Pressure sensor with display. PN-,25-RBR14-MFRKG/US/ /V

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Two switching outputs, one of them programmable as analogue output. Clearly visible 4-digit LED display. Country-specific pressure units selectable. With long-term stability thanks to high overload protection. Selectable output polarity

Parametry techniczne

Output signal: switching signal; analogue signal; IO-Link; (configurable)
Measuring range: -0.0125...0.25 bar -12.5...250 mbar -5...100.4 inH2O -1.25...25 kPa
-0.0125...0.25 bar: -12.5...250 mbar
Process connection: threaded connection G 1/4 internal thread
Special feature: Gold-plated contacts
Application: for industrial applications
Media: liquids and gases
Medium temperature [°C]: -25...80
Min. bursting pressure: 30000 mbar 12000 inH2O 3000 kPa
30000 mbar: 12000 inH2O
Pressure rating: 6000 mbar 2400 inH2O 600 kPa
6000 mbar: 2400 inH2O
Type of pressure: relative pressure
Operating voltage [V]: 18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]: < 35
Min. insulation resistance [MΩ]: 100; (500 V DC)
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 0.3
Integrated watchdog: yes
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Output signal: switching signal; analogue signal; IO-Link; (configurable)
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2
Permanent current rating of switching output DC [mA]: 250
Switching frequency DC [Hz]: < 500
Number of analogue outputs: 1
Analogue current output [mA]: 4...20; (scalable 1:4)
Max. load [Ω]: (Ub - 10 V) / 20 mA
Analogue voltage output [V]: 0...10; (scalable 1:4)
Min. load resistance [Ω]: 2000
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Measuring range: -0.0125...0.25 bar -12.5...250 mbar -5...100.4 inH2O -1.25...25 kPa
-0.0125...0.25 bar: -12.5...250 mbar
Set point SP: -10.5...250 mbar -4.2...100.4 inH2O -1.05...25 kPa
-10.5...250 mbar: -4.2...100.4 inH2O
Reset point rP: -11.5...249 mbar -4.6...100 inH2O -1.15...24.9 kPa
-11.5...249 mbar: -4.6...100 inH2O
Analogue start point: -12.5...187.5 mbar -5...75.4 inH2O -1.25...10 kPa
-12.5...187.5 mbar: -5...75.4 inH2O
Analogue end point: 50...250 mbar 20.2...100.4 inH2O 5...25 kPa
50...250 mbar: 20.2...100.4 inH2O
In steps of: 0.5 mbar 0.2 inH2O 0.05 kPa
0.5 mbar: 0.2 inH2O
Factory setting: SP1 = 62.5 mbar rP1 = 57.5 mbar SP2 = 187.5 mbar rP2 = 182.5 mbar ASP = 0.0 mbar AEP = 250.0 mbar
Switch point accuracy [% of the span]: < ± 0,4; (Turn down 1:1)
Repeatability [% of the span]: < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]: < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]: < ± 0,1; (Turn down 1:1)
Long-term stability [% of the span]: < ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K]: < ± 0,2; (0...80 °C)
Temperature coefficient span [% of the span / 10 K]: < ± 0,2; (0...80 °C)
Response time [ms]: < 1.5
Damping for the switching output dAP [s]: 0.01...4
Damping for the analogue output dAA [s]: 0.01...4
Max. response time analogue output [ms]: 3
Parameter setting options: hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.0
IO-Link device ID: 63 d / 00 00 3F h
Profiles: no profile
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 65
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-5 Surge: 0,5/1 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN IEC 68-2-27 50 g (11 ms)
DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance: DIN IEC 68-2-6 20 g (10...2000 Hz)
DIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [years]: 131
Pressure Equipment Directive: Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]: 261
Materials: stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE
Materials (wetted parts): stainless steel (1.4305 / 303); ceramics; FKM
Min. pressure cycles: 100 million
Process connection: threaded connection G 1/4 internal thread
Restrictor element integrated: no (can be retrofitted)
Display: Display unit 4 x LED, green switching status 2 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit
Display unit: 4 x LED, green
switching status: 2 x LED, yellow
function display: alphanumeric display, 4-digit
measured values: alphanumeric display, 4-digit
Display unit: mbar; kPa; inH2O; mmWS
Notes: discontinued article
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Parametry logistyczne

ECCN:
Kraj pochodzenia: RO
EAN:
Waga: 0,26 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m