PIM094
Pressure sensor with diagnostic function for pumps. PIM010-RES30-KFPKG/US/ /P
Two functions in one unit: Pump monitoring and pressure detection. Reliable diagnosis of disturbances in the suction area and detection of cavitation. Detection of outgassing liquids or trapped air in the pump. Independent system-pressure monitoring with second switching output. Pump control via analogue output
| Output signal: | switching signal; analogue signal; (configurable) |
| Measuring range: | -1...10 bar -14.5...145 psi -0.1...1 MPa |
| -1...10 bar: | -14.5...145 psi |
| Process connection: | threaded connection Aseptoflex external thread Aseptoflex |
| Special feature: | Gold-plated contacts |
| Application: | food and beverage industry |
| Installation: | freely rotatable housing 350° |
| Media: | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C]: | -25...125; (145 max. 1h) |
| Min. bursting pressure: | 150 bar 2175 psi 15 MPa |
| 150 bar: | 2175 psi |
| Pressure rating: | 50 bar 725 psi 5 Mpa |
| 50 bar: | 725 psi |
| Type of pressure: | relative pressure |
| No dead space: | yes |
| Operating voltage [V]: | 18...32 DC |
| Current consumption [mA]: | < 50 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | 0.2 |
| Integrated watchdog: | yes |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; (configurable) |
| Electrical design: | PNP |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2 |
| Permanent current rating of switching output DC [mA]: | 250 |
| Switching frequency DC [Hz]: | 350 |
| Notes on switching frequency: | OUT2 |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20, invertible; (scalable) |
| Max. load [Ω]: | (Ub - 10 V) / 20 mA |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Measuring range: | -1...10 bar -14.5...145 psi -0.1...1 MPa |
| -1...10 bar: | -14.5...145 psi |
| Set point SP: | -0.98...10 bar -14.2...145 psi -0.098...1 MPa |
| -0.98...10 bar: | -14.2...145 psi |
| Reset point rP: | -1...9.98 bar -14.5...144.7 psi -0.1...0.998 MPa |
| -1...9.98 bar: | -14.5...144.7 psi |
| Analogue start point: | -1...7.25 bar -14.5...105.1 psi -0.1...0.725 MPa |
| -1...7.25 bar: | -14.5...105.1 psi |
| Analogue end point: | 1.5...10 bar 21.8...145 psi 0.15...1 MPa |
| 1.5...10 bar: | 21.8...145 psi |
| In steps of: | 0.01 bar 0.1 psi 0.001 MPa |
| 0.01 bar: | 0.1 psi |
| Factory setting: | OU1 = Fnc OU2 = I ASP = 0.00 bar AEP = 10.00 bar |
| Switch point accuracy [% of the span]: | < ± 0,2; (Turn down 1:1) |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span]: | < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
| Linearity deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
| Hysteresis deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
| Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,15; (0...70 °C) |
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,1; (0...70 °C) |
| Response time [ms]: | < 2.5 |
| Damping for the switching output dAP [s]: | 0...10 |
| Damping for the analogue output dAA [s]: | 0...10 |
| Step response time analogue output [ms]: | 0.2 |
| Parameter setting options: | zero point; span |
| Ambient temperature [°C]: | -25...80 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 67; IP 69K |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-5 Surge: | 0,5/1 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
| DIN IEC 68-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 188 |
| Weight [g]: | 414.5 |
| Materials: | stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE |
| Materials (wetted parts): | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
| Min. pressure cycles: | 100 million |
| Process connection: | threaded connection Aseptoflex external thread Aseptoflex |
| Display: | Display unit 4 x LED, green switching status 2 x LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
| Display unit: | 4 x LED, green |
| switching status: | 2 x LED, yellow |
| function display: | alphanumeric display, 4-digit |
| measured values: | alphanumeric display, 4-digit |
| Remarks: | pump diagnosis for pumps with constant rotational speed (+/- 10 % deviation of the taught rotational speed) speed range 40...3000 U/min minimum pressure for pump diagnosis 0,5 bar The 3-A qualification is only valid if adapters with 3-A qualification are used for installation. |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,41 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |