PI2889
Flush pressure sensor with display. PI-,10BREA01-MFRKG/US/ /P
Robust stainless steel housing for use in the food and beverage industry. Hygienic, flush design. Resistant to high-pressure cleaning with aggressive cleaning agents. High temperature resistance and high protection rating. Programmable analogue and switching output
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) | 
| Measuring range: | -0.005...0.1 bar -5...100 mbar -2...40.16 inH2O -0.5...10 kPa | 
| -0.005...0.1 bar: | -5...100 mbar | 
| Process connection: | threaded connection G 1 external thread sealing cone | 
| Special feature: | Gold-plated contacts | 
| Application: | food and beverage industry | 
| Media: | viscous media and liquids with suspended particles; liquids and gases | 
| Medium temperature [°C]: | -25...125; (145 max. 1h) | 
| Min. bursting pressure: | 30000 mbar 12044 inH2O 3000 kPa | 
| 30000 mbar: | 12044 inH2O | 
| Pressure rating: | 4000 mbar 1606 inH2O 400 kPa | 
| 4000 mbar: | 1606 inH2O | 
| Vacuum resistance [mbar]: | -1000 | 
| Type of pressure: | relative pressure | 
| MAWP (for applications according to CRN) [bar]: | 4 | 
| Min. insulation resistance [MΩ]: | 100; (500 V DC) | 
| Protection class: | III | 
| Reverse polarity protection: | yes | 
| Integrated watchdog: | yes | 
| Operating voltage [V]: | 20...32 DC | 
| Current consumption [mA]: | 3.6...21 | 
| Power-on delay time [s]: | 1 | 
| Operating voltage [V]: | 18...32 DC | 
| Current consumption [mA]: | < 45 | 
| Power-on delay time [s]: | 0.5 | 
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Total number of outputs: | 2 | 
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) | 
| Electrical design: | PNP/NPN | 
| Number of digital outputs: | 2 | 
| Output function: | normally open / normally closed; (parameterisable) | 
| Number of analogue outputs: | 1 | 
| Analogue current output [mA]: | 4...20, invertible; (scalable) | 
| Short-circuit protection: | yes | 
| Type of short-circuit protection: | pulsed | 
| Overload protection: | yes | 
| Max. load [Ω]: | 300 | 
| Max. voltage drop switching output DC [V]: | 2 | 
| Permanent current rating of switching output DC [mA]: | 250 | 
| Switching frequency DC [Hz]: | 125 | 
| Max. load [Ω]: | (Ub - 10 V) / 20 mA | 
| Measuring range: | -0.005...0.1 bar -5...100 mbar -2...40.16 inH2O -0.5...10 kPa | 
| -0.005...0.1 bar: | -5...100 mbar | 
| Set point SP: | -4.8...100 mbar -1.92...40.16 inH2O -0.48...10 kPa | 
| -4.8...100 mbar: | -1.92...40.16 inH2O | 
| Reset point rP: | -5...99.8 mbar -2...40.08 inH2O -0.5...9.98 kPa | 
| -5...99.8 mbar: | -2...40.08 inH2O | 
| Analogue start point: | -5...75 mbar -2...30.12 inH2O -0.5...7.5 kPa | 
| -5...75 mbar: | -2...30.12 inH2O | 
| Analogue end point: | 20...100 mbar 8.04...40.16 inH2O 2...10 kPa | 
| 20...100 mbar: | 8.04...40.16 inH2O | 
| In steps of: | 0.1 mbar 0.04 inH2O 0.01 kPa | 
| 0.1 mbar: | 0.04 inH2O | 
| Factory setting: | SP1 = 25 mbar rP1 = 23 mbar SP2 = 75 mbar rP2 = 73 mbar ASP =0 mbar AEP = 100 mbar | 
| Switch point accuracy [% of the span]: | < ± 0,5; (Turn down 1:1) | 
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | 
| Characteristics deviation [% of the span]: | < ± 0,5; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) | 
| Linearity deviation [% of the span]: | < ± 0,25; (Turn down 1:1) | 
| Hysteresis deviation [% of the span]: | < ± 0,2; (Turn down 1:1) | 
| Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) | 
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1; (0...70 °C) | 
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...70 °C) | 
| Damping for the switching output dAP [s]: | 0...30 | 
| Damping for the analogue output dAA [s]: | 0.01...99.99 | 
| Step response time analogue output [ms]: | 45 | 
| Min. response time of switching output (dAP) [ms]: | 3 | 
| Step response time analogue output [ms]: | 7 | 
| Communication interface: | IO-Link | 
| Transmission type: | COM2 (38,4 kBaud) | 
| IO-Link revision: | 1.0 | 
| IO-Link device ID: | 259 d / 00 01 03 h | 
| Profiles: | no profile | 
| SIO mode: | yes | 
| Required master port type: | A | 
| Process data analogue: | 1 | 
| Process data binary: | 2 | 
| Min. process cycle time [ms]: | 2.3 | 
| Ambient temperature [°C]: | -25...80 | 
| Storage temperature [°C]: | -40...100 | 
| Protection: | IP 67; IP 68; IP 69K | 
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V | 
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD | 
| EN 61000-4-3 HF radiated: | 10 V/m | 
| EN 61000-4-4 Burst: | 2 kV | 
| EN 61000-4-5 Surge: | 0,5/1 kV | 
| EN 61000-4-6 HF conducted: | 10 V | 
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) | 
| DIN IEC 68-2-27: | 50 g (11 ms) | 
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) | 
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) | 
| MTTF [years]: | 148.85 | 
| Note on approval: | factory certificate available as download at www.factory-certificate.ifm | 
| UL approval: | UL Approval no. J019 | 
| UL Approval no.: | J019 | 
| Weight [g]: | 376.5 | 
| Materials: | stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA | 
| Materials (wetted parts): | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE | 
| Min. pressure cycles: | 100 million | 
| Process connection: | threaded connection G 1 external thread sealing cone | 
| Display: | Display unit LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit | 
| Display unit: | LED, green | 
| switching status: | LED, yellow | 
| function display: | alphanumeric display, 4-digit | 
| measured values: | alphanumeric display, 4-digit | 
| Display unit: | mbar; kPa; inH2O; mmWS; % of the span | 
| Remarks: | Attention: The unit must only be installed in a process connection for G1 sealing cone. The G1A sealing cone of the unit is only suited for adapters with metal end stop. | 
| Pack quantity: | 1 pcs. | 
| Connection: | Connector: 1 x M12; Contacts: gold-plated | 
| ECCN: | |
| Kraj pochodzenia: | DE | 
| EAN: | |
| Waga: | 0,38 kg | 
| Długość: | 0,00 m | 
| Szerokość: | 0,00 m | 
| Wysokość: | 0,00 m |