PI2815
Flush pressure sensor with display. PI-006-REA01-MFRKG/US/ /P
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
| Measuring range: | -1...6 bar -14.5...87 psi -100...600 kPa |
| -1...6 bar: | -14.5...87 psi |
| Process connection: | threaded connection G 1 external thread sealing cone |
| Special feature: | Gold-plated contacts |
| Application: | food and beverage industry |
| Media: | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C]: | -25...125; (145 max. 1h) |
| Min. bursting pressure: | 100 bar 1450 psi 10000 kPa |
| 100 bar: | 1450 psi |
| Pressure rating: | 30 bar 435 psi 3000 kPa |
| 30 bar: | 435 psi |
| Vacuum resistance [mbar]: | -1000 |
| Type of pressure: | relative pressure; vacuum |
| No dead space: | yes |
| MAWP (for applications according to CRN) [bar]: | 30 |
| Min. insulation resistance [MΩ]: | 100; (500 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Integrated watchdog: | yes |
| Operating voltage [V]: | 20...32 DC |
| Current consumption [mA]: | 3.6...21 |
| Power-on delay time [s]: | 1 |
| Operating voltage [V]: | 18...32 DC |
| Current consumption [mA]: | < 45 |
| Power-on delay time [s]: | 0.5 |
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Number of analogue outputs: | 1 |
| Analogue current output [mA]: | 4...20, invertible; (scalable) |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | pulsed |
| Overload protection: | yes |
| Max. load [Ω]: | 300 |
| Max. voltage drop switching output DC [V]: | 2 |
| Permanent current rating of switching output DC [mA]: | 250 |
| Switching frequency DC [Hz]: | 125 |
| Max. load [Ω]: | (Ub - 10 V) / 20 mA |
| Measuring range: | -1...6 bar -14.5...87 psi -100...600 kPa |
| -1...6 bar: | -14.5...87 psi |
| Set point SP: | -0.99...6 bar -14.4...87 psi -99...600 kPa |
| -0.99...6 bar: | -14.4...87 psi |
| Reset point rP: | -1...5.99 bar -14.5...86.9 psi -100...599 kPa |
| -1...5.99 bar: | -14.5...86.9 psi |
| Analogue start point: | -1...4.5 bar -14.5...65.3 psi -100...450 kPa |
| -1...4.5 bar: | -14.5...65.3 psi |
| Analogue end point: | 0.5...6 bar 7.3...87 psi 50...600 kPa |
| 0.5...6 bar: | 7.3...87 psi |
| In steps of: | 0.005 bar 0.1 psi 0.5 kPa |
| 0.005 bar: | 0.1 psi |
| Factory setting: | SP1 = 1.5 bar rP1 = 1.38 bar SP2 = 4.5 bar rP2 = 4.380 bar ASP = 0.0 bar AEP = 6.0 bar |
| Switch point accuracy [% of the span]: | < ± 0,2; (Turn down 1:1) |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span]: | < ± 0,2; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) |
| Linearity deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
| Hysteresis deviation [% of the span]: | < ± 0,15; (Turn down 1:1) |
| Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,05; (0...70 °C) |
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,15; (0...70 °C) |
| Damping for the switching output dAP [s]: | 0...30 |
| Damping for the analogue output dAA [s]: | 0.01...99.99 |
| Step response time analogue output [ms]: | 45 |
| Min. response time of switching output (dAP) [ms]: | 3 |
| Step response time analogue output [ms]: | 7 |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.0 |
| IO-Link device ID: | 728 d / 00 02 d8 h |
| Profiles: | no profile |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 1 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 2.3 |
| Ambient temperature [°C]: | -25...80 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 67; IP 68; IP 69K |
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated: | 10 V/m |
| EN 61000-4-4 Burst: | 2 kV |
| EN 61000-4-5 Surge: | 0,5/1 kV |
| EN 61000-4-6 HF conducted: | 10 V |
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
| DIN IEC 68-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) |
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 154 |
| Note on approval: | factory certificate available as download at www.factory-certificate.ifm |
| Weight [g]: | 377 |
| Materials: | stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
| Materials (wetted parts): | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
| Min. pressure cycles: | 100 million |
| Process connection: | threaded connection G 1 external thread sealing cone |
| Display: | Display unit LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
| Display unit: | LED, green |
| switching status: | LED, yellow |
| function display: | alphanumeric display, 4-digit |
| measured values: | alphanumeric display, 4-digit |
| Display unit: | bar; kPa; psi; % of the span |
| Remarks: | Attention: The unit must only be installed in a process connection for G1 sealing cone. The G1A sealing cone of the unit is only suited for adapters with metal end stop. |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,38 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |