PH0104
PH-010-RES30-KFPKG/US/ /P
Flush pressure sensor. PH-010-RES30-KFPKG/US/ /P
Combined level measurement and point level detection with analogue / switching output. Resistant to high-pressure cleaning with aggressive cleaning agents. With long-term stability thanks to high repeatability and low linearity error. Hygienic design for the requirements of the food and beverage industry. Flush mount installation in containers, tanks and pipes
| Output signal: | switching signal; analogue signal; (configurable) | 
| Measuring range: | -0.5...10 bar -7...145 psi -50...1000 kPa | 
| -0.5...10 bar: | -7...145 psi | 
| Process connection: | 1,5" | 
| Special feature: | Gold-plated contacts | 
| Application: | food and beverage industry | 
| Installation: | freely rotatable housing 350° | 
| Media: | viscous media and liquids with suspended particles; liquids and gases | 
| Medium temperature [°C]: | -25...80 | 
| Min. bursting pressure: | 150 bar 2175 psi 15000 kPa | 
| 150 bar: | 2175 psi | 
| Pressure rating: | 50 bar 725 psi 5000 kPa | 
| 50 bar: | 725 psi | 
| Type of pressure: | relative pressure | 
| No dead space: | yes | 
| Operating voltage [V]: | 20...30 DC | 
| Current consumption [mA]: | < 60 | 
| Min. insulation resistance [MΩ]: | 100; (500 V DC) | 
| Protection class: | III | 
| Reverse polarity protection: | yes | 
| Power-on delay time [s]: | 0.2 | 
| Integrated watchdog: | yes | 
| Number of inputs and outputs: | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Total number of outputs: | 2 | 
| Output signal: | switching signal; analogue signal; (configurable) | 
| Electrical design: | PNP/NPN | 
| Number of digital outputs: | 2 | 
| Output function: | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V]: | 2 | 
| Permanent current rating of switching output DC [mA]: | 250 | 
| Switching frequency DC [Hz]: | < 170 | 
| Number of analogue outputs: | 1 | 
| Analogue current output [mA]: | 4...20; (scalable 1:4) | 
| Max. load [Ω]: | (Ub - 10 V) / 20 mA | 
| Analogue voltage output [V]: | 0...10; (scalable 1:4) | 
| Min. load resistance [Ω]: | 2000 | 
| Short-circuit protection: | yes | 
| Type of short-circuit protection: | pulsed | 
| Overload protection: | yes | 
| Measuring range: | -0.5...10 bar -7...145 psi -50...1000 kPa | 
| -0.5...10 bar: | -7...145 psi | 
| Set point SP: | -0.45...9.99 bar -7...145 psi -45...999 kPa | 
| -0.45...9.99 bar: | -7...145 psi | 
| Reset point rP: | -0.5...9.94 bar -7...144 psi -50...994 kPa | 
| -0.5...9.94 bar: | -7...144 psi | 
| Analogue start point: | -0.5...7.49 bar -7...109 psi -50...749 kPa | 
| -0.5...7.49 bar: | -7...109 psi | 
| Analogue end point: | 2...9.99 bar 29...145 psi 200...999 kPa | 
| 2...9.99 bar: | 29...145 psi | 
| In steps of: | 0.01 bar 1 psi 1 kPa | 
| 0.01 bar: | 1 psi | 
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | 
| Characteristics deviation [% of the span]: | < ± 0,6; (Turn down 1:1 linearity, incl. hysteresis and repeatability limit value setting to DIN 16086) | 
| Linearity deviation [% of the span]: | < ± 0,5; (Turn down 1:1) | 
| Hysteresis deviation [% of the span]: | < ± 0,1; (Turn down 1:1) | 
| Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per year) | 
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,1; (0...80 °C) | 
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,2; (0...80 °C) | 
| Response time [ms]: | < 3 | 
| Damping for the switching output dAP [s]: | 0...4 | 
| Damping for the analogue output dAA in steps [s]: | 0 - 0,1 - 0,5 - 2 | 
| Max. response time analogue output [ms]: | 3 | 
| Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span | 
| Ambient temperature [°C]: | -25...80 | 
| Storage temperature [°C]: | -40...100 | 
| Protection: | IP 67 | 
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V | 
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD | 
| EN 61000-4-3 HF radiated: | 10 V/m | 
| EN 61000-4-4 Burst: | 2 kV | 
| EN 61000-4-6 HF conducted: | 10 V | 
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) | 
| DIN IEC 68-2-27: | 50 g (11 ms) | 
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) | 
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) | 
| Weight [g]: | 341.5 | 
| Materials: | stainless steel (1.4404 / 316L); PBT; PC; PEI; EPDM/X; FKM | 
| Materials (wetted parts): | stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); PTFE | 
| Min. pressure cycles: | 100 million | 
| Process connection: | 1,5" | 
| Display: | switching status 2 x LED, red function display 7-segment LED display measured values 7-segment LED display | 
| switching status: | 2 x LED, red | 
| function display: | 7-segment LED display | 
| measured values: | 7-segment LED display | 
| Display unit: | bar; psi; kPa | 
| Pack quantity: | 1 pcs. | 
| Connection: | Connector: 1 x M12; Contacts: gold-plated | 
| ECCN: | |
| Kraj pochodzenia: | DEUTSCHLAND | 
| EAN: | |
| Waga: | 0,36 kg | 
| Długość: | 0,00 m | 
| Szerokość: | 0,00 m | 
| Wysokość: | 0,00 m |