PG2489
Pressure sensor with analogue display. PG-,10BREB12-MFRKG/US/ /P
Analogue display, pressure switch and transmitter in one unit. Excellent readability also over a long distance. Rotatable display with LED bar graph for switch point indication. Programmable switching output and scalable analogue output. Robust stainless steel housing for use in harsh industrial environments
| Output signal: | switching signal; analogue signal; (configurable) | 
| Measuring range: | -0.005...0.1 bar -5...100 mbar -2...40.16 inH2O | 
| -0.005...0.1 bar: | -5...100 mbar | 
| Process connection: | threaded connection G 1/2 external thread | 
| Special feature: | Gold-plated contacts | 
| Application: | for industrial applications; Safety manometer (S) based on DIN EN 837-1 | 
| Media: | liquids and gases | 
| Medium temperature [°C]: | -25...80 | 
| Min. bursting pressure: | 30000 mbar 12044 inH2O | 
| 30000 mbar: | 12044 inH2O | 
| Pressure rating: | 4000 mbar 1606 inH2O | 
| 4000 mbar: | 1606 inH2O | 
| Type of pressure: | relative pressure | 
| Operating voltage [V]: | 18...32 DC | 
| Current consumption [mA]: | < 70; (24 V) | 
| Min. insulation resistance [MΩ]: | 100; (500 V DC) | 
| Protection class: | III | 
| Reverse polarity protection: | yes | 
| Power-on delay time [s]: | 6 | 
| Integrated watchdog: | yes | 
| Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 | 
| Total number of outputs: | 2 | 
| Output signal: | switching signal; analogue signal; (configurable) | 
| Electrical design: | PNP/NPN | 
| Number of digital outputs: | 1 | 
| Output function: | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V]: | 2 | 
| Permanent current rating of switching output DC [mA]: | 250 | 
| Switching frequency DC [Hz]: | 75 | 
| Number of analogue outputs: | 1 | 
| Analogue current output [mA]: | 4...20, invertible; (scalable) | 
| Max. load [Ω]: | (Ub - 10 V) / 20 mA | 
| Short-circuit protection: | yes | 
| Type of short-circuit protection: | pulsed | 
| Overload protection: | yes | 
| Measuring range: | -0.005...0.1 bar -5...100 mbar -2...40.16 inH2O | 
| -0.005...0.1 bar: | -5...100 mbar | 
| Set point SP: | -4.6...160 mbar -1.84...64.24 inH2O | 
| -4.6...160 mbar: | -1.84...64.24 inH2O | 
| Reset point rP: | -5...159.6 mbar -2...64.08 inH2O | 
| -5...159.6 mbar: | -2...64.08 inH2O | 
| Analogue start point: | -5...135 mbar -2...54.24 inH2O | 
| -5...135 mbar: | -2...54.24 inH2O | 
| Analogue end point: | 20...160 mbar 8...64.24 inH2O | 
| 20...160 mbar: | 8...64.24 inH2O | 
| In steps of: | 0.2 mbar 0.08 inH2O | 
| 0.2 mbar: | 0.08 inH2O | 
| Switch point accuracy [% of the span]: | < ± 0,6; (Turn down 1:1) | 
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | 
| Characteristics deviation [% of the span]: | < ± 0,35 (BFSL) / < ± 0,6 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line) | 
| Hysteresis deviation [% of the span]: | < ± 0,5; (Turn down 1:1) | 
| Long-term stability [% of the span]: | < ± 0,1; (Turn down 1:1; per 6 months) | 
| Temperature coefficient zero point [% of the span / 10 K]: | < ± 0,3; (0...70 °C) | 
| Temperature coefficient span [% of the span / 10 K]: | < ± 0,3; (0...70 °C) | 
| Response time [ms]: | < 9 | 
| Damping for the switching output dAP [s]: | 0.01...30 | 
| Damping for the analogue output dAA [s]: | 0.01...30 | 
| Step response time analogue output [ms]: | 28 | 
| Ambient temperature [°C]: | -20...80 | 
| Storage temperature [°C]: | -40...100 | 
| Protection: | IP 67; IP 69K | 
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V | 
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD | 
| EN 61000-4-3 HF radiated: | 10 V/m | 
| EN 61000-4-4 Burst: | 2 kV | 
| EN 61000-4-5 Surge: | 0,5/1 kV | 
| EN 61000-4-6 HF conducted: | 10 V | 
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) | 
| DIN IEC 68-2-27: | 50 g (11 ms) | 
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) | 
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) | 
| MTTF [years]: | 103 | 
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | 
| Weight [g]: | 611 | 
| Materials: | stainless steel (1.4404 / 316L); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm | 
| Materials (wetted parts): | Al2O3 (ceramics); FKM; stainless steel (1.4404 / 316L) | 
| Min. pressure cycles: | 100 million | 
| Process connection: | threaded connection G 1/2 external thread | 
| Restrictor element integrated: | no (can be retrofitted) | 
| Display: | Display unit 2 x LED, green switching status LED, yellow switch points LED ring, red function display alphanumeric display, red 4-digit measured values analogue display, 0...350° rotatable, pointer not visible when unit disconnected measured values alphanumeric display, red 4-digit | 
| Display unit: | 2 x LED, green | 
| switching status: | LED, yellow | 
| switch points: | LED ring, red | 
| function display: | alphanumeric display, red 4-digit | 
| measured values: | analogue display, 0...350° rotatable, pointer not visible when unit disconnected | 
| measured values: | alphanumeric display, red 4-digit | 
| With scale: | yes | 
| Extended display range (max.): | 160 mbar 64.24 inH2O | 
| 160 mbar: | 64.24 inH2O | 
| Remarks: | switch point accuracy in the extended display range: 1.5 % of the span | 
| Pack quantity: | 1 pcs. | 
| Connection: | Connector: 1 x M12; Contacts: gold-plated | 
| ECCN: | |
| Kraj pochodzenia: | DE | 
| EAN: | |
| Waga: | 0,61 kg | 
| Długość: | 0,00 m | 
| Szerokość: | 0,00 m | 
| Wysokość: | 0,00 m |