PE3003
Pressure sensor with display. PE-025-RDR14-MFPKG/US/ /E
Special seal for use in cleaning processes. With programmable switching output and analogue output. With long-term stability thanks to high overload protection. Clearly visible 4-digit LED display. High shock and vibration resistance
| Output signal: | switching signal; analogue signal; (configurable) | 
| Measuring range: | 0...25 bar 0...363 psi 0...2.5 MPa | 
| 0...25 bar: | 0...363 psi | 
| Process connection: | threaded connection G 1/4 internal thread | 
| Special feature: | Gold-plated contacts | 
| Application: | for industrial applications | 
| Media: | liquids and gases | 
| Cannot be used for: | oils | 
| Medium temperature [°C]: | -25...80 | 
| Min. bursting pressure: | 350 bar 5075 psi 35 MPa | 
| 350 bar: | 5075 psi | 
| Pressure rating: | 150 bar 2175 psi 15 Mpa | 
| 150 bar: | 2175 psi | 
| Type of pressure: | relative pressure | 
| Operating voltage [V]: | 18...36 DC; (according to EN 50178 SELV/PELV) | 
| Current consumption [mA]: | < 50 | 
| Min. insulation resistance [MΩ]: | 100; (500 V DC) | 
| Protection class: | III | 
| Reverse polarity protection: | yes | 
| Overvoltage protection: | yes; (< 40 V) | 
| Power-on delay time [s]: | 0.3 | 
| Integrated watchdog: | yes | 
| Number of inputs and outputs: | Number of digital outputs: 1; Number of analogue outputs: 1 | 
| Total number of outputs: | 2 | 
| Output signal: | switching signal; analogue signal; (configurable) | 
| Electrical design: | PNP | 
| Number of digital outputs: | 1 | 
| Output function: | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V]: | 2 | 
| Permanent current rating of switching output DC [mA]: | 250 | 
| Switching frequency DC [Hz]: | < 170 | 
| Number of analogue outputs: | 1 | 
| Analogue current output [mA]: | 4...20 | 
| Max. load [Ω]: | 500 | 
| Analogue voltage output [V]: | 0...10 | 
| Min. load resistance [Ω]: | 2000 | 
| Short-circuit protection: | yes | 
| Type of short-circuit protection: | pulsed | 
| Measuring range: | 0...25 bar 0...363 psi 0...2.5 MPa | 
| 0...25 bar: | 0...363 psi | 
| Set point SP: | 0.2...25 bar 4...362 psi 0.02...2.5 MPa | 
| 0.2...25 bar: | 4...362 psi | 
| Reset point rP: | 0.1...24.9 bar 2...360 psi 0.01...2.49 MPa | 
| 0.1...24.9 bar: | 2...360 psi | 
| In steps of: | 0.1 bar 2 psi 0.01 MPa | 
| 0.1 bar: | 2 psi | 
| Factory setting: | SP1 = 6.3 bar rP1 = 5.8 bar | 
| Switch point accuracy [% of the span]: | < ± 0,5 | 
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) | 
| Characteristics deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | 
| Hysteresis deviation [% of the span]: | < ± 0,25 | 
| Long-term stability [% of the span]: | < ± 0,05; (per 6 months) | 
| Temperature coefficient zero point [% of the span / 10 K]: | 0,2; (-20...80 °C) | 
| Temperature coefficient span [% of the span / 10 K]: | 0,2; (-20...80 °C) | 
| Delay time programmable dS, dr [s]: | 0; 0,2...50 | 
| Max. response time analogue output [ms]: | 3 | 
| Parameter setting options: | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output | 
| Ambient temperature [°C]: | -20...80 | 
| Storage temperature [°C]: | -40...100 | 
| Protection: | IP 67 | 
| EMC: | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V | 
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD | 
| EN 61000-4-3 HF radiated: | 10 V/m | 
| EN 61000-4-4 Burst: | 2 kV | 
| EN 61000-4-5 Surge: | 0,5/1 kV | 
| EN 61000-4-6 HF conducted: | 10 V | 
| Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) | 
| DIN IEC 68-2-27: | 50 g (11 ms) | 
| Vibration resistance: | DIN IEC 68-2-6 20 g (10...2000 Hz) | 
| DIN IEC 68-2-6: | 20 g (10...2000 Hz) | 
| MTTF [years]: | 231 | 
| Pressure Equipment Directive: | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | 
| Weight [g]: | 261 | 
| Materials: | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE | 
| Materials (wetted parts): | stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); sealing of the measuring cell: EPDM | 
| Min. pressure cycles: | 100 million | 
| Process connection: | threaded connection G 1/4 internal thread | 
| Display: | Display unit 3 x LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit | 
| Display unit: | 3 x LED, green | 
| switching status: | LED, yellow | 
| function display: | alphanumeric display, 4-digit | 
| measured values: | alphanumeric display, 4-digit | 
| Pack quantity: | 1 pcs. | 
| Connection: | Connector: 1 x M12; Contacts: gold-plated | 
| ECCN: | |
| Kraj pochodzenia: | DE | 
| EAN: | |
| Waga: | 0,26 kg | 
| Długość: | 0,00 m | 
| Szerokość: | 0,00 m | 
| Wysokość: | 0,00 m |