PC9050
Pressure transmitter. PT-400-SBG14-C-DVG/ /W
Precise linear 0.5...4.5 V output signal for mobile applications. High repeatability and low linearity error. With long-term stability thanks to high overload protection. Robust stainless steel housing for use in mobile machines. Large operating temperature range and high protection rating
| Output signal: | analogue signal |
| Measuring range [bar]: | 0...400 |
| Process connection: | threaded connection G 1/4 external thread |
| Application: | for mobile applications |
| Media: | liquids and gases |
| Medium temperature [°C]: | -25...90; (on request: -40...100 °C) |
| Min. bursting pressure [bar]: | 1600 |
| Pressure rating [bar]: | 600 |
| Type of pressure: | relative pressure |
| Operating voltage [V]: | 5 DC; (ratiometric) |
| Current consumption [mA]: | < 6 |
| Min. insulation resistance [MΩ]: | 100; (80 V DC) |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Number of inputs and outputs: | Number of analogue outputs: 1 |
| Total number of outputs: | 1 |
| Output signal: | analogue signal |
| Number of analogue outputs: | 1 |
| Analogue voltage output [V]: | 0.5...4.5 |
| Min. load resistance [Ω]: | 5000 |
| Measuring range [bar]: | 0...400 |
| Repeatability [% of the span]: | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span]: | < ± 1,0; (incl. drift when overtightened, zero point and span error) |
| Linearity deviation [% of the span]: | < ± 0,25 (BFSL) / < ± 0,5 (LS) |
| Hysteresis deviation [% of the span]: | < ± 0,2 |
| Long-term stability [% of the span]: | < ± 0,1; (per 6 months) |
| Temperature drift per 10 K: | < ± 0.5 |
| Step response time analogue output [ms]: | 8 |
| Ambient temperature [°C]: | -25...90 |
| Storage temperature [°C]: | -40...100 |
| Protection: | IP 67; IP 69K |
| EMC: | immunity according to the automotive directive 1995/54/EC ISO 11452-2 100 V/m ISO 11452-4 100 mA / severity level 4 DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD DIN EN 61000-6-2 radiation of interference CISPR 25 DIN EN 61000-6-3 |
| immunity: | according to the automotive directive 1995/54/EC |
| ISO 11452-2: | 100 V/m |
| ISO 11452-4: | 100 mA / severity level 4 |
| DIN EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
| Shock resistance: | DIN EN 60068-2-27 50 g (11 ms) |
| DIN EN 60068-2-27: | 50 g (11 ms) |
| Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
| DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
| MTTF [years]: | 3896 |
| UL approval: | UL Approval no. J04X |
| UL Approval no.: | J04X |
| Weight [g]: | 80.5 |
| Materials: | stainless steel (1.4404 / 316L); PA |
| Materials (wetted parts): | stainless steel (1.4404 / 316L); FKM |
| Min. pressure cycles: | 50 million |
| Process connection: | threaded connection G 1/4 external thread |
| Restrictor element integrated: | yes |
| Remarks: | BFSL = Best Fit Straight Line LS = limit value setting |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12 |
| ECCN: | |
| Kraj pochodzenia: | RO |
| EAN: | |
| Waga: | 0,08 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |