Ifm O1D120

Photoelectric distance sensor. O1DLF3KG/IO-LINK

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Reliable optical distance measurement with high ranges up to 10 m. Two switching outputs, one of them programmable as IO-Link and one as analogue output. Scalable measuring range and window function. Use in applications with background suppression. Excellent price/performance ratio

Parametry techniczne

Communication interface: IO-Link
Laser protection class: 2
Housing: rectangular
Dimensions [mm]: 59 x 42 x 52
Special feature: Background suppression
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 150
Protection class: III
Reverse polarity protection: yes
Typ. lifetime [h]: 50000
Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Total number of outputs: 2
Electrical design: PNP
Number of digital outputs: 2
Output function: normally open / normally closed; (programmable)
Max. current load per output [mA]: 200
Number of analogue outputs: 1
Analogue current output [mA]: 4...20
Max. load [Ω]: 250
Analogue voltage output [V]: 0...10
Min. load resistance [Ω]: 5000
Short-circuit protection: yes
Type of short-circuit protection: pulsed
Overload protection: yes
Max. light spot width [mm]: 15
Max. light spot height [mm]: 15
Light spot dimensions refer to: 10 m
Background suppression available: yes
Background suppression [m]: 0...19
Measuring range [m]: 0.2...10; (white paper 200 x 200 mm 90% remission)
Sampling rate [Hz]: 1...50
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 806 d / 00 03 26 h
Profiles: Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 2
Process data binary: 3
Min. process cycle time [ms]: 6
Ambient temperature [°C]: -10...60
Protection: IP 67
EMC: EN 60947-5-2
Laser protection class: 2
Notes on laser protection: Caution: laser light Power: <= 4,0 mW Wave length: 650 nm pulse: 1,3 ns Do not stare into beam. Avoid exposure to the laser light. laser class: 2 EN / IEC60825-1:2007 EN / IEC60825-1:2014 Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
Caution:: laser light
Power:: <= 4,0 mW
Wave length:: 650 nm
pulse:: 1,3 ns
laser class:: 2
Weight [K40]: 314
Housing: rectangular
Dimensions [mm]: 59 x 42 x 52
Materials: housing: diecast zinc; front lens: glass; LED window: PC
Lens alignment: side lens
Display: switching status 2 x LED, yellow operation LED, green distance value, programming alphanumeric display, 4-digit
switching status: 2 x LED, yellow
operation: LED, green
distance value, programming: alphanumeric display, 4-digit
Accessories (optional): Protective cover, E21133
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12
Parameter: Setting range
Uni: mm, m, inch
OU1: Hno, Hnc, Fno, Fnc
SP1 [mm]: 200...9999
nSP1 [mm]: 200...9999
FSP1 [mm]: 200...9999
OU2: Hno, Hnc, Fno, Fnc, I, U
SP2 [mm]: 200...9999
nSP2 [mm]: 200...9999
FSP2 [mm]: 200...9999
ASP [mm]: 0...9999
AEP [mm]: 0...9999
rATE [Hz]: 1...50
dS1 [s]: 0...0.1...5
dr1 [s]: 0...0.1...5
dS2 [s]: 0...0.1...5
dr2 [s]: 0...0.1...5
dFo [s]: 0...0.1...5
dIS: d1...3 ; rd1...3; OFF
read/write distance (mm): repeatability of the measured values
200...1000 mm: ± 5.0 mm
1000...2000 mm: ± 5.5 mm
2000...4000 mm: ± 17.5 mm
4000...6000 mm: ± 27.5 mm
6000...10000 mm: ± 60.0 mm
Sampling rate: 50 Hz
Extraneous light on the object: < 40 klx
read/write distance (mm): repeatability of the measured values
200...1000 mm: ± 16.5 mm
1000...2000 mm: ± 16.5 mm
2000...4000 mm: ± 30.0 mm
4000...6000 mm: ± 37.0 mm
6000...10000 mm: ± 75.0 mm
Sampling rate: 50 Hz
Extraneous light on the object: 40...100 klx
read/write distance (mm): repeatability of the measured values
200...1000 mm: ± 4.0 mm
1000...2000 mm: ± 4.5 mm
2000...4000 mm: ± 13.5 mm
4000...6000 mm: ± 19.0 mm
6000...10000 mm: ± 37.0 mm
Sampling rate: 1 Hz
Extraneous light on the object: < 40 klx
read/write distance (mm): repeatability of the measured values
200...1000 mm: ± 10.0 mm
1000...2000 mm: ± 10.0 mm
2000...4000 mm: ± 17.0 mm
4000...6000 mm: ± 22.0 mm
6000...10000 mm: ± 37.0 mm
Range on black object (6 % remission): <= 4000 mm
Extraneous light on the object: < 40...100 klx
constant ambient conditions: 23 °C / 960 hPa
minimum power-on time in minutes: 10

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,31 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m