Ifm N0032A

Switching amplifiers for Namur sensors. NV1221/115VAC/RL/1D/1G

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

For the operation of intrinsically safe sensors in hazardous areas. Reliable short-circuit and wire-break monitoring. Easy programming of the output function. LED display to check operation, switching status and function. Quick and easy mounting on DIN rail

Parametry techniczne

Application: short-circuit monitoring; Wire monitoring
Operating voltage tolerance [%]: -10...10
Operating voltage [V]: < 115 AC
Power consumption [W]: 1.3
Number of channels: 2
Electrical design: relay; (per channel: 1 changeover contact)
Contact rating: 253 V AC / 2 A / cos phi > 0,7 // 40 V DC / 2 A; (ohmic resistance)
Switching frequency AC [Hz]: 10
Ambient temperature [°C]: -20...60
Protection: IP 20
Approval: PTB 02 ATEX 2035; TIIS TC16048; IECEx PTB 17.0023
ATEX marking: II (1) G [Ex ia Ga] IIC
EMC: EN 50081-2 (1993) EN 61326-1 (2006)
EN 50081-2: (1993)
EN 61326-1: (2006)
MTTF [years]: 458
Weight [g]: 217
Switching cycles mechanical: 10 million
Display: switching status 2 x LED, yellow operation LED, green function 2 x LED, red
switching status: 2 x LED, yellow
operation: LED, green
function: 2 x LED, red
Remarks: Caution The control monitor must be mounted outside the hazardous area. Free terminals must not be used.
Pack quantity: 1 pcs.
Connection: terminals: ...2.5 mm²
in protection rating intrinsic safety: [EEx ia] IIC
Voltage [V]: 10.6
Current [mA]: 19.1
Power [mW]: 51
External inductance [mH]: 97
External capacitance [µF]: 2.32

Parametry logistyczne

ECCN:
Kraj pochodzenia: ID
EAN:
Waga: 0,22 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m