Ifm LMC400

Sensor for point level detection. LMGCE-C12E-QSKG-0/US

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

For the reliable level control in tanks and containers. Two programmable switching outputs, one of them with IO-Link communication interface. Preset to water and hydrous media. Simple process connection via screw-in adapter. Reliable suppression of deposits or foam

Parametry techniczne

Number of inputs and outputs: Number of digital outputs: 2
Factory setting: water; hydrous media
Process connection: G 1/2 external thread
Special feature: Gold-plated contacts
Media: water; hydrous media; oils; oil-based media; coolants; powder
Cannot be used for: See the operating instructions, chapter "Function and features".
Medium temperature [°C]: -25...100
Probe length [mm]: 9.6
Tank pressure [bar]: -1...40
MAWP (for applications according to CRN) [bar]: 40
Medium temperature [°C]: -25...100
Operating voltage [V]: 18...30 DC
Current consumption [mA]: < 35
Protection class: III
Reverse polarity protection: yes
Number of inputs and outputs: Number of digital outputs: 2
Total number of outputs: 2
Output signal: switching signal; IO-Link
Electrical design: PNP/NPN
Number of digital outputs: 2
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 50; (100 (...60 °C))
Short-circuit protection: yes
Type of short-circuit protection: thermal, pulsed
Overload protection: yes
Factory setting: water; hydrous media
Response time [s]: < 0.5
Communication interface: IO-Link
Transmission type: COM2 (38,4 kBaud)
IO-Link revision: 1.1
SDCI standard: IEC 61131-9
IO-Link device ID: 0x0002A2
Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode: yes
Required master port type: A
Process data analogue: 1
Process data binary: 2
Min. process cycle time [ms]: 2.3
Ambient temperature [°C]: -25...85
Note on ambient temperature: for installation in probe observe the temperature in the pipe, see installation instructions
Storage temperature [°C]: -40...85
Protection: IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68)
EMC: DIN EN 61000-6-2 DIN EN 61000-6-3 : closed tanks DIN EN 61000-6-4 : open tanks
DIN EN 61000-6-3: : closed tanks
DIN EN 61000-6-4: : open tanks
Shock resistance: DIN EN 60068-2-27 50 g (11 ms)
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 20 g (10...2000 Hz)
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]: 534
UL approval: UL Approval no. H004
UL Approval no.: H004
Weight [g]: 127.5
Dimensions [mm]: Ø 18.1 / L = 76.2
Materials: stainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts): stainless steel (1.4404 / 316L); PEEK; FKM
Process connection: G 1/2 external thread
Display: switching status LEDs, yellow operating status LEDs, green
switching status: LEDs, yellow
operating status: LEDs, green
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,13 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m