Ifm LL8024

Continuous level sensor with leakage monitoring. LL0728B-B-00KVPKG/US

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Reliable level detection in containers and tanks. For use in water, oils and coolants. Easy adjustment to the medium to be measured. Clearly visible 4-digit LED display. Two programmable switching outputs for leakage detection

Parametry techniczne

Number of inputs and outputs: Number of digital outputs: 4
Probe length L [mm]: 728
Special feature: Gold-plated contacts
Media: hydrous coolants; oils; water; media similar to water
Dielectric constant of the medium: > 2
Cannot be used for: extremely conductive media; adhering media; granulates; bulk material; acids; alkali
Tank pressure [bar]: 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019)
Medium temperature [°C]: 0...35; (LL8024 + E43102: 0...55; For water and hydrous media with temperatures > 35 °C install the unit into a climatic tube.)
Medium temperature [°C]: 0...70
Medium temperature short time [°C]: 0...90
Medium temperature [°C]: 0...35; (LL8024 + E43102: 0...55; For water and hydrous media with temperatures > 35 °C install the unit into a climatic tube.)
Operating voltage [V]: 18...30 DC; (operating voltage "supply class 2" according to cULus)
Current consumption [mA]: < 60
Protection class: III
Reverse polarity protection: yes
Power-on delay time [s]: 3
Number of inputs and outputs: Number of digital outputs: 4
Total number of outputs: 4
Output signal: switching signal
Electrical design: PNP
Number of digital outputs: 4
Output function: normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]: 2.5
Permanent current rating of switching output DC [mA]: 200
Short-circuit protection: yes
Type of short-circuit protection: thermal, pulsed
Overload protection: yes
Probe length L [mm]: 728
Active range A [mm]: 585
Inactive range I1 / I2 [mm]: 102 / 40
Set point SP [mm]: 60...580
Reset point rP [mm]: 50...570
In steps of [mm]: 10
Hysteresis [mm]: 10
Overflow switch point OP [mm]: 200 - 240 - 280 - 310 - 350 - 390 - 420 - 460 - 500 - 530 - 570 -610
Hysteresis, OP [mm]: 4
Display range [°C]: -10...100
Measuring error [% of the final value]: ± 5
Repeatability: ± 2
Parameter setting options: hysteresis / window; normally open / normally closed; SP/rP position; OP position; adjustment OP; medium selection; offset setting; Display unit; settings for leakage monitoring
Ambient temperature [°C]: 0...60
Storage temperature [°C]: -25...80
Protection: IP 67
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance: DIN EN 60068-2-29 15 g (11 ms)
DIN EN 60068-2-29: 15 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 5 g (10...2000 Hz)
DIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]: 202
Weight [g]: 534.8
Dimensions [mm]: Ø 16
Materials: stainless steel (1.4301 / 304); FKM; NBR; PBT; PC; PEI; PP; TPE-V
Materials (wetted parts): PP
Display: display unit / status 4 x LED, green switching status 4 x LED, yellow level alphanumeric display, 4-digit parameter setting alphanumeric display, 4-digit
display unit / status: 4 x LED, green
switching status: 4 x LED, yellow
level: alphanumeric display, 4-digit
parameter setting: alphanumeric display, 4-digit
Notes: discontinued article; For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet).
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,53 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m