LK1024
Electronic level sensor. LK0728B-B-00KQPKG/US
| Number of inputs and outputs: | Number of digital outputs: 2 |
| Factory setting: | hydrous coolants; water; media similar to water |
| Probe length L [mm]: | 728 |
| Special feature: | Gold-plated contacts |
| Media: | hydrous coolants; oils; oil-based media; water; media similar to water |
| Dielectric constant of the medium: | > 2 |
| Cannot be used for: | extremely conductive media; adhering media; granulates; bulk material; acids; alkali; food and electroplating industry |
| Maximum speed of the change of level [mm/s]: | 300 |
| Tank pressure [bar]: | 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) |
| Medium temperature [°C]: | 0...35; (with climatic tube E43102: 35...55 °C) |
| Medium temperature [°C]: | 0...70 |
| Medium temperature short time [°C]: | 0...90; (< 1 h) |
| Medium temperature [°C]: | 0...35; (with climatic tube E43102: 35...55 °C) |
| Operating voltage [V]: | 18...30 DC |
| Current consumption [mA]: | < 50 |
| Protection class: | III |
| Reverse polarity protection: | yes |
| Power-on delay time [s]: | < 3 |
| Number of inputs and outputs: | Number of digital outputs: 2 |
| Total number of outputs: | 2 |
| Output signal: | switching signal; IO-Link |
| Electrical design: | PNP/NPN |
| Number of digital outputs: | 2 |
| Output function: | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V]: | 2.5 |
| Permanent current rating of switching output DC [mA]: | 200 |
| Short-circuit protection: | yes |
| Type of short-circuit protection: | thermal, pulsed |
| Overload protection: | yes |
| Factory setting: | hydrous coolants; water; media similar to water |
| Probe length L [mm]: | 728 |
| Active range A [mm]: | 585 |
| Inactive range I1 / I2 [mm]: | 104 / 39 |
| Set point SP [mm]: | 60...590 |
| Reset point rP [mm]: | 50...580 |
| In steps of [mm]: | 10 |
| Reference point OP [mm]: | 200 - 240 - 280 - 310 - 350 - 390 - 420 - 460 - 500 - 530 - 570 - 610- OFF |
| Hysteresis, OP [mm]: | 4 |
| Measuring error [% of the final value]: | ± 5 |
| Repeatability: | ± 2 |
| Resolution [mm]: | 5 |
| Parameter setting options: | hysteresis / window; normally open / normally closed; switching logic; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay |
| Communication interface: | IO-Link |
| Transmission type: | COM2 (38,4 kBaud) |
| IO-Link revision: | 1.1 |
| SDCI standard: | IEC 61131-9 |
| IO-Link device ID: | 0x00028E |
| Profiles: | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode: | yes |
| Required master port type: | A |
| Process data analogue: | 2 |
| Process data binary: | 2 |
| Min. process cycle time [ms]: | 3.2 |
| Ambient temperature [°C]: | 0...60 |
| Storage temperature [°C]: | -25...80 |
| Protection: | IP 67 |
| EMC: | DIN EN 61000-6-4 DIN EN 61000-6-2 |
| Shock resistance: | DIN EN 60068-2-29 15 g (11 ms) |
| DIN EN 60068-2-29: | 15 g (11 ms) |
| Vibration resistance: | DIN EN 60068-2-6 5 g (10...2000 Hz) |
| DIN EN 60068-2-6: | 5 g (10...2000 Hz) |
| MTTF [years]: | 265 |
| Weight [g]: | 545 |
| Dimensions [mm]: | Ø 16 |
| Materials: | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV |
| Materials (wetted parts): | PP |
| Display: | display unit / status 2 x LED, green (cm, inch) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit parameter setting alphanumeric display, 4-digit |
| display unit / status: | 2 x LED, green (cm, inch) |
| switching status: | 2 x LED, yellow |
| measured values: | alphanumeric display, 4-digit |
| parameter setting: | alphanumeric display, 4-digit |
| Notes: | Please see the technical note under "Downloads" |
| Pack quantity: | 1 pcs. |
| Connection: | Connector: 1 x M12; Contacts: gold-plated |
| ECCN: | |
| Kraj pochodzenia: | RO |
| EAN: | |
| Waga: | 0,55 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |