KD001A
Capacitive sensor. KDE2060-FBOA/NI/3D
With combined AC/DC output and two-wire technology. Long sensing range of 60 mm. Easy setting of the sensing range via potentiometer. For applications in hazardous areas. Robust housing for use in harsh industrial environments
| Output function: | normally open / normally closed; (selectable) |
| Sensing range [mm]: | 60 |
| Housing: | rectangular |
| Dimensions [mm]: | 105 x 80 x 42 |
| Operating voltage [V]: | 20...250 AC/DC |
| Protection class: | II |
| Reverse polarity protection: | no |
| Output function: | normally open / normally closed; (selectable) |
| Max. voltage drop switching output DC [V]: | 8 |
| Max. voltage drop switching output AC [V]: | 10 |
| Minimum load current [mA]: | 5 |
| Max. leakage current [mA]: | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.3 (24 V DC) |
| Permanent current rating of switching output AC [mA]: | 130; (250 (...40 °C)) |
| Permanent current rating of switching output DC [mA]: | 130; (250 (...40 °C)) |
| Short-time current rating of switching output [mA]: | 1500; (20 ms / 0,5 Hz) |
| Switching frequency AC [Hz]: | 4 |
| Switching frequency DC [Hz]: | 4 |
| Notes on switching frequency: | only for resistive loads; 2 Hz for utilisation category AC-140 |
| Short-circuit proof: | no |
| Overload protection: | no |
| Sensing range [mm]: | 60 |
| Sensing range adjustable: | yes |
| Factory setting sensing range [mm]: | 60 |
| Real sensing range Sr [mm]: | 60 ± 10 % |
| Correction factor: | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
| Hysteresis [% of Sr]: | 1...15 |
| Switch point drift [% of Sr]: | -15...15 |
| Ambient temperature [°C]: | -20...60 |
| Protection: | IP 65 |
| Increased immunity: | yes |
| ATEX marking: | II 3D Ex tc IIIC T90°C Dc X IP65 |
| EMC: | EN 60947-5-2 |
| MTTF [years]: | 270 |
| Weight [g]: | 281.5 |
| Housing: | rectangular |
| Mounting: | non-flush mountable |
| Dimensions [mm]: | 105 x 80 x 42 |
| Materials: | PPE modified; PA |
| Tightening torque [Nm]: | housing screws: 0,9 Nm; screws: 4 Nm |
| Display: | switching status 1 x LED, yellow |
| switching status: | 1 x LED, yellow |
| Required protection: | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. |
| Remarks: | Recommendation: Check the safe functioning of the unit after a short circuit. |
| Pack quantity: | 1 pcs. |
| Connection: | terminals: 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm; Cable gland: M20 X 1.5 |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,28 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |