IN0131
Inductive sensor. INE2004DABOA
| Output function: | 2 x normally open | 
| Sensing range [mm]: | 4 | 
| Housing: | rectangular | 
| Dimensions [mm]: | 33 x 60 x 92 | 
| Operating voltage [V]: | 20...250 AC/DC | 
| Current consumption [mA]: | < 15 | 
| Protection class: | II | 
| Reverse polarity protection: | yes | 
| Output function: | 2 x normally open | 
| Max. voltage drop switching output DC [V]: | 6 | 
| Max. voltage drop switching output AC [V]: | 6.5 | 
| Minimum load current [mA]: | 5 | 
| Max. leakage current [mA]: | 2.5 (250 V AC) / 1.3 (110 V AC) / 0.8 (24 V DC) | 
| Permanent current rating of switching output AC [mA]: | 250; (350 (...50 °C)) | 
| Permanent current rating of switching output DC [mA]: | 100 | 
| Short-time current rating of switching output [mA]: | 2200; (20 ms / 0,5 Hz) | 
| Switching frequency AC [Hz]: | 25 | 
| Switching frequency DC [Hz]: | 50 | 
| Short-circuit protection: | no | 
| Overload protection: | no | 
| Sensing range [mm]: | 4 | 
| Real sensing range Sr [mm]: | 4 ± 10 % | 
| Operating distance [mm]: | 0...3.25 | 
| Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 | 
| Hysteresis [% of Sr]: | 1...15 | 
| Switch point drift [% of Sr]: | -10...10 | 
| Ambient temperature [°C]: | -25...70 | 
| Protection: | IP 67 | 
| EMC: | EN 60947-5-2 | 
| MTTF [years]: | 307 | 
| UL approval: | Ta -25...70 °C Enclosure type Type 1 voltage supply Hazardous voltage File number UL E174191 | 
| Ta: | -25...70 °C | 
| Enclosure type: | Type 1 | 
| voltage supply: | Hazardous voltage | 
| File number UL: | E174191 | 
| Weight [g]: | 174.8 | 
| Housing: | rectangular | 
| Mounting: | non-flush mountable | 
| Dimensions [mm]: | 33 x 60 x 92 | 
| Materials: | housing: PA | 
| Display: | switching status 2 x LED, yellow | 
| switching status: | 2 x LED, yellow | 
| Required protection: | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting | 
| Accessories (supplied): | washers: 2 cylinder screws: 2 x M5 x 18 | 
| Remarks: | Recommendation: Check the safe functioning of the unit after a short circuit. | 
| Pack quantity: | 1 pcs. | 
| Connection: | terminal strip in the terminal chamber: | 
| ECCN: | |
| Kraj pochodzenia: | DE | 
| EAN: | |
| Waga: | 0,17 kg | 
| Długość: | 0,00 m | 
| Szerokość: | 0,00 m | 
| Wysokość: | 0,00 m |