Ifm IM002A

Inductive sensor. IME2040-FBOA/3D

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

For applications in hazardous areas. With combined AC/DC output and two-wire technology. Output function normally open / normally closed programmable. Robust housing for use in harsh industrial environments. Five positions of the sensing face selectable

Parametry techniczne

Output function: normally open / normally closed; (selectable)
Sensing range [mm]: 40
Housing: rectangular
Dimensions [mm]: 40 x 40 x 105
Operating voltage [V]: 20...250 AC/DC
Protection class: II
Reverse polarity protection: no
Output function: normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V]: 6
Max. voltage drop switching output AC [V]: 6.5
Minimum load current [mA]: 5
Max. leakage current [mA]: 2.5 (250 V AC) / 1.3 (130 V AC) / 0.8 (24 V DC)
Permanent current rating of switching output AC [mA]: 150
Permanent current rating of switching output DC [mA]: 100
Short-time current rating of switching output [mA]: 2200; (20 ms / 0,5 Hz)
Switching frequency AC [Hz]: 10
Switching frequency DC [Hz]: 10
Notes on switching frequency: only for resistive loads; 2 Hz for utilisation category AC-140
Short-circuit proof: no
Overload protection: no
Sensing range [mm]: 40
Real sensing range Sr [mm]: 40 ± 10 %
Operating distance [mm]: 0...32.4
Correction factor: steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2
Hysteresis [% of Sr]: 1...20
Switch point drift [% of Sr]: -10...10
Ambient temperature [°C]: -20...60
Protection: IP 65; IP 67
ATEX marking: II 3D Ex tc IIIC T95°C Dc X
EMC: EN 60947-5-2
MTTF [years]: 554
Weight [g]: 253
Housing: rectangular
Mounting: non-flush mountable
Dimensions [mm]: 40 x 40 x 105
Materials: PC; PA; stainless steel
Display: switching status 1 x LED, yellow
switching status: 1 x LED, yellow
Required protection: miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area.
Remarks: Recommendation: Check the safe functioning of the unit after a short circuit. 5 positions of the active zone possible
Pack quantity: 1 pcs.
Connection: terminals: 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm

Parametry logistyczne

ECCN:
Kraj pochodzenia: RO
EAN:
Waga: 0,25 kg
Długość: 0,00 m
Szerokość: 0,00 m