Ifm II5920

Inductive sensor. IIKC012BASKG/US-104

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Parametry techniczne

Electrical design: PNP/NPN
Output function: normally open
Sensing range [mm]: 12
Housing: threaded type
Dimensions [mm]: M30 x 1.5 / L = 70
Special feature: Gold-plated contacts; Increased sensing range
Operating voltage [V]: 10...36 DC
Current consumption [mA]: < 10; (only in 3-wire operation)
Protection class: II
Reverse polarity protection: yes
Electrical design: PNP/NPN
Output function: normally open
Max. voltage drop switching output DC [V]: 2.5
Minimum load current [mA]: 2; (only in 2-wire operation)
Max. leakage current [mA]: 0.5; (only in 2-wire operation)
Permanent current rating of switching output DC [mA]: 100
Switching frequency DC [Hz]: 100
Short-circuit protection: yes
Overload protection: yes
Sensing range [mm]: 12
Operating distance [mm]: 0...9.72
Increased sensing range: yes
Correction factor: steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.45 / copper: 0.35
Hysteresis [% of Sr]: 1...20
Ambient temperature [°C]: -40...85
Protection: IP 67; IP 69K
EMC: EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 30 V/m EN 61000-4-4 Burst 2 V EN 61000-4-5 Surge 0,5 kV mains line to line EN 61000-4-6 HF conducted 10 V EN 55011 class B
EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 30 V/m
EN 61000-4-4 Burst: 2 V
EN 61000-4-5 Surge: 0,5 kV mains line to line
EN 61000-4-6 HF conducted: 10 V
EN 55011: class B
Vibration resistance: EN 60068-2-6 Fc 20 g (10...3000 Hz) / -20...50 °C 50 sweep cycles per frequency; 1 octave per minute in 3 axes
EN 60068-2-6 Fc: 20 g (10...3000 Hz) / -20...50 °C
Shock resistance: EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C
EN 60068-2-27 Ea: 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C
Continuous shock resistance: EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C
EN 60068-2-27: 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C
Salt spray test: EN 60068-2-52 Kb severity level 5 (4 test cycles)
EN 60068-2-52 Kb: severity level 5 (4 test cycles)
MTTF [years]: 1101
UL approval: Ta -40...85 °C Enclosure type Type 1 voltage supply Limited Voltage/Current File number UL E174191
Ta: -40...85 °C
Enclosure type: Type 1
voltage supply: Limited Voltage/Current
File number UL: E174191
Weight [K40]: 132
Housing: threaded type
Mounting: flush mountable
Dimensions [mm]: M30 x 1.5 / L = 70
Thread designation: M30 x 1.5
Materials: housing: stainless steel; sensing face: LCP natural; connector housing: PEI; lock nuts: brass
Display: switching status 4 x 90° LED, yellow
switching status: 4 x 90° LED, yellow
Accessories (supplied): lock nuts: 2
Pack quantity: 1 pcs.

Parametry logistyczne

ECCN:
Kraj pochodzenia: RO
EAN:
Waga: 0,13 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m