IGM215
Inductive sensor. IGKC008BATKG/M/PH
| Electrical design: | NPN | 
| Output function: | normally open | 
| Sensing range [mm]: | 8 | 
| Housing: | threaded type | 
| Dimensions [mm]: | M18 x 1 / L = 81 | 
| Special feature: | Increased sensing range | 
| Application: | Use in mobile and harsh applications | 
| Operating voltage [V]: | 10...36 DC | 
| Current consumption [mA]: | < 10 | 
| Protection class: | II | 
| Reverse polarity protection: | yes | 
| Electrical design: | NPN | 
| Output function: | normally open | 
| Max. voltage drop switching output DC [V]: | 2.5 | 
| Max. leakage current [mA]: | 0.5 | 
| Permanent current rating of switching output DC [mA]: | 100 | 
| Switching frequency DC [Hz]: | 200 | 
| Short-circuit protection: | yes | 
| Type of short-circuit protection: | pulsed | 
| Overload protection: | yes | 
| Sensing range [mm]: | 8 | 
| Operating distance [mm]: | 0...6.48 | 
| Increased sensing range: | yes | 
| Correction factor: | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.45 / copper: 0.35 | 
| Hysteresis [% of Sr]: | 1...20 | 
| Ambient temperature [°C]: | -40...85 | 
| Protection: | IP 67; IP 69K | 
| EMC: | noise immunity according to DIN ISO 11452-2 100 V/m conducted interference acc. to ISO 7637-2 pulse 1 2 3a 3b 4 5 severity level IV IV IV IV IV IV failure criterion C C A A A C EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV line to line, Ri: 2 Ohm EN 61000-4-6 HF conducted 10 V EN 55011 class B | 
| noise immunity according to DIN ISO 11452-2: | 100 V/m | 
| pulse: | 1 2 3a 3b 4 5 | 
| severity level: | IV IV IV IV IV IV | 
| failure criterion: | C C A A A C | 
| EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD | 
| EN 61000-4-3 HF radiated: | 10 V/m | 
| EN 61000-4-4 Burst: | 2 kV | 
| EN 61000-4-5 Surge: | 0,5 kV line to line, Ri: 2 Ohm | 
| EN 61000-4-6 HF conducted: | 10 V | 
| EN 55011: | class B | 
| Continuous shock resistance: | EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C | 
| EN 60068-2-27: | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C | 
| Fast temperature change: | EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles | 
| EN 60068-2-14 Na: | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles | 
| Salt spray test: | EN 60068-2-52 Kb severity level 5 (4 test cycles) | 
| EN 60068-2-52 Kb: | severity level 5 (4 test cycles) | 
| MTTF [years]: | 1192 | 
| Weight [g]: | 87.2 | 
| Housing: | threaded type | 
| Mounting: | flush mountable | 
| Dimensions [mm]: | M18 x 1 / L = 81 | 
| Thread designation: | M18 x 1 | 
| Materials: | housing: stainless steel (1.4404 / 316L); sensing face: LCP | 
| Tightening torque [Nm]: | 50 | 
| Display: | switching status 4 x 90° LED, yellow | 
| switching status: | 4 x 90° LED, yellow | 
| Accessories (supplied): | lock nuts: 2 | 
| Pack quantity: | 1 pcs. | 
| Connection: | Cable: 2 m, PUR; burning behaviour to ECE R118 rev. 2; 3 x 0.5 mm² | 
| ECCN: | |
| Kraj pochodzenia: | DE | 
| EAN: | |
| Waga: | 0,09 kg | 
| Długość: | 0,00 m | 
| Szerokość: | 0,00 m | 
| Wysokość: | 0,00 m |