Ifm GG714S

Fail-safe inductive sensor. GIGA4008-2PS/SIL2/V4A/US

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

For ensuring machine safety. Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849. No special actuator for electronic fail-safe sensors required. Connection to safety PLC, safe AS-i modules or safe evaluation units

Parametry techniczne

Electrical design: PNP
Output function: 2 x OSSD (A1 and A2)
Enable zone [mm]: 0...6.5
Housing: threaded type
Dimensions [mm]: M18 x 1 / L = 71.5
Special feature: Gold-plated contacts
Type of operation: continuous operation (maintenance-free)
Application: industrial application
Operating voltage [V]: 19.2...30 DC
Rated insulation voltage [V]: 30
Current consumption [mA]: < 30
Protection class: III
Reverse polarity protection: yes
Max. power-on delay time [ms]: 1000
Electrical design: PNP
Output function: 2 x OSSD (A1 and A2)
Max. voltage drop switching output DC [V]: 2.5; (30 mA)
Permanent current rating of switching output DC [mA]: 100
Output data: Interface type C class 1
Output voltage at 24 V: compatible with EN 61131-2 inputs type 1, 2
Short-circuit protection: yes
Overload protection: no
Max. capacitive load CL_max [nF]: 20
Enable zone [mm]: 0...6.5
Safe switching-off distance s(ar) [mm]: 11
Response time to safety request [ms]: 1
Response time when approaching the enable zone [ms]: 1
Risk time (response time for safety-related faults) [ms]: 20
Ambient temperature [°C]: -40...70
Rate of temperature change [K/min]: 0.5
Max. relative air humidity [%]: briefly: 5...95 %; permanent: 5...70 %
Air pressure [kPa]: 80...106
Max. height above sea level [m]: 2000
Ionising radiation: not permissible
Salt spray: IEC 60068-2-52
Protection: IP 65; IP 67; IP 69K; (with ifm socket duly screwed on)
UV radiation: DIN ISO 4892-1, DIN ISO 4892-2
Chemical media: test according to ISO 16750-5 The following media were tested for 22 hours at 75 °C Liebherr Hydraulik 37 Liebherr Hydraulik Gear ATF Liebherr Hydraulik Plus Arctic diesel biodiesel brake fluid urea The following media were tested for 22 hours at 25 °C battery acid cold cleaner ammonia-based cleaner The following media were tested for 2 hours at 25 °C wheel rim cleaner
The following media were tested for 22 hours at 75 °C: Liebherr Hydraulik 37
The following media were tested for 22 hours at 25 °C: battery acid
The following media were tested for 2 hours at 25 °C: wheel rim cleaner
EMC: IEC 60947-5-2 IEC 60947-5-3 EN 60947-5-3 EN 61000-4-2 ESD 6 kV CD / 8 kV AD EN 61000-4-3 HF radiated 20 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 61000-4-8 30 A/m EN 55011 class B
EN 61000-4-2 ESD: 6 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 20 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V
EN 61000-4-8: 30 A/m
EN 55011: class B
Shock resistance: IEC 60947-5-2
Vibration resistance: IEC 60947-5-2
ISO 13849-1: category 2, PL d
IEC 61508: SIL 2
IEC 62061: SIL cl 2
Mission time TM [h]: ≤ 87600
Mission time TM (additional indication): 10 years
Safety-related reliability PFHD [1/h]: 1.0E-07
Weight [g]: 136
Housing: threaded type
Mounting: non-flush mountable
Dimensions [mm]: M18 x 1 / L = 71.5
Thread designation: M18 x 1
Materials: housing: stainless steel (1.4571/316Ti ) ; cover: PBT; plug: PPS GF40
Accessories (supplied): lock nuts: 2
Remarks: Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range. (FE360 = ST37K) 24x24x1 mm
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,14 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m