Housing: housing for DIN rail mounting
Dimensions [mm]: 75 x 55 x 110
Application: universal evaluation of pulse sequences with regard to overspeed and underspeed; rotational speed monitoring
Nominal voltage AC [V]: 27...60
Nominal voltage DC [V]: 27...60
Nominal voltage tolerance [%]: < 10
Nominal voltage tolerance 2 [%]: 20...10
Nominal frequency AC [Hz]: 50...60
Auxiliary energy for sensors DC [V]: 24; (≤ 30 mA)
Number of inputs and outputs: Number of relay outputs: 1
Number of relay outputs: 1
Contact rating: 6 A (250 V AC); B300, R300
Analogue current output [mA]: ...200
Analogue voltage output [V]: ...24
Setting range [Imp/min]: 5...5000
Hysteresis [% of Sr]: 5...100
Repeatability [% of Sr]: 1
Start-up delay [s]: 0.5...15
Adjustment of the switch point: fine adjustment within the range with potentiometer
Ambient temperature [°C]: -20...70
Protection: IP 40
Protection rating terminals: IP 20
MTTF [years]: 308
Weight [g]: 289.6
Housing: housing for DIN rail mounting
Dimensions [mm]: 75 x 55 x 110
Materials: plastics
Display: switching status LED, green operation 1 x LED, green
switching status: LED, green
operation: 1 x LED, green
Notes: discontinued article