AC007S
Universal module 2SI 2xOSSD
Safe AS-Interface universal module. Universal module 2SI 2xOSSD
For the connection of electro-sensitive protective equipment (ESPE). Integration of safety-related components in AS-i. Safe signal detection using two OSSD inputs. Device connection via M12 sockets or cage clamps. Clearly visible powerful LEDs for displaying operation, switching status and error
Application: | connection of electro-sensitive protective equipment (ESPE) type 4 according to EN 61496-1 |
Operating voltage [V]: | 26.5...31.6 DC |
Current consumption [mA]: | < 35 |
Protection class: | III |
Input circuit of digital inputs: | PNP |
Sensor supply of the inputs: | ext. 24 V DC PELV |
Voltage supply [V]: | 20.4...28.8 |
Max. total current rating of inputs [mA]: | 2000 |
Input current High [mA]: | 6...10 |
Input current Low [mA]: | 0...2 |
Switching level high [V]: | > 11 |
Switching level low [V]: | < 5 |
Digital inputs protected against short circuits: | yes |
Overload protection digital inputs: | yes |
Electrical design: | AS-i |
Ambient temperature [°C]: | -25...55 |
Storage temperature [°C]: | -25...85 |
Max. relative air humidity [%]: | 95 |
Protection: | IP 67 |
EMC: | EN 50295 IEC 62026-2 |
ISO 13849-1: | category 4, PL e |
IEC 61508: | SIL 3 |
Mission time TM [h]: | 87600 |
Mission time TM (additional indication): | 10 years calculation basis Ambient temperature: 40 °C |
Safety-related reliability PFHD [1/h]: | 1.54E-09 |
Max. internal capacitance [nF]: | 10 |
AS-i version: | 2.11; 3.0 |
Extended addressing mode possible: | no |
AS-i profile: | S-0.B.E |
AS-i I/O configuration [hex]: | 0 |
AS-i ID code [hex]: | B.E |
AS-i certificate: | 80002 |
Weight [g]: | 280 |
Materials: | PA 6 |
Display: | operation LED, green errors LED, red function LED, yellow |
operation: | LED, green |
errors: | LED, red |
function: | LED, yellow |
Pack quantity: | 1 pcs. |
ECCN: | |
Kraj pochodzenia: | SINGAPUR |
EAN: | |
Waga: | 0,28 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |